TYROLIT Hydrostress AG Overview of flash code The flash code is used for fault detection and is displayed in red on the group alarm light on the remote controller. Flash code indicators Flash code for fault indicators Flash code Example 3x Fault Possible cause Action 2x Mains phase is missing • Fault during installation • Fuse defective • Check phases and fuses 3x DC motors are overheating • Absence of cooling • Allow machine to cool for 3 minutes • Avoid direct contact with sunlight Blade motor is overheating • Absence of cooling • No, too little or too hot cooling water • See Technical data, chapter 7.10 4x Wall saw WSE811 Short circuit fault • Contact TYROLIT Hydrostress AG after-sales service Short circuit detection • Earth fault • Contact TYROLIT Hydrostress AG after-sales service Main motor overcurrent • Main motor blocked • Overcurrent earth fault • Contact TYROLIT Hydrostress AG after-sales service Main motor earth fault • Electrical connection earth fault • Contact TYROLIT Hydrostress AG after-sales service Page 29