Download X2 Benchtop PID Digital Temperature Controller
Transcript
X2 Benchtop PID Digital Temperature Controller Technical Specifications X2 Benchtop PID Digital Temperature Controller Dimensions Thermocouple 2 types Standards: IPTS/68/DIN 43710 CJC rejection: 20:1 (0.05°/°C) typical External resistance: 100Ω maximum Calibration accuracy: ±0.25%SM ±1°C (SM = sensor maximum) Sensor Range: J Type: 0°C (32°F) to 800°C (1472°F), Linearity 0.5 Sampling frequency: Input 10Hz, CJC 2 sec. Common mode rejection: Negligible effect up to 140dB, 240V, 50-60Hz K Type: -50°C (-58°F) to 1200°C (2192°F), Linearity 0.25 Series mode rejection: 60dB, 50-60Hz Temperature coefficient: 150ppm/°C SM Reference conditions: 22°C ±2°C, rated voltage after 15 minutes settling time. Display: 4 Digits, high brightness Green LED, 10mm (0.4”) high. Digital range: -199 to 9999 Hi-res mode: -199.9 to 999.9 Keypad: 3 elastomeric buttons LED output indicators: SP1 round, green or red; SP2 round, green or red Part Number Matrix and Accessories PART NUMBER MATRIX: X2 - XXX Y Z CONFIGURATION / OPTIONS TABLE TOP (T) INCLUDES STAND CLAMP (S) THERMOCOUPLE / SENSOR INPUT J TYPE (J) K TYPE (K) INPUT VOLTAGE 120 VAC (120) 240 VAC (240) Accessories: TAJN05-AA Type J Thermocouple; mini connector; 5ft (1.5m) TAJN10-AA Type J Thermocouple; mini connector; 10ft (3.0m) TAKN05-DA Type K Thermocouple; mini connector; 5ft (1.5m) TAKN10-DA Type K Thermocouple; mini connector; 10ft (3.0m) © BriskHeat® Corporation. All rights reserved. 5 © BriskHeat® Corporation. All rights reserved. 6