Download c - SVB
Transcript
BATTERY TYPE: GREEN: gel/sealed YELLOW: open lead acid RED: A.G.M.sealed 1 2 1 2 4 1 2 a k a = yellow to ignition (or D+/L/61) b = white to field c = brown to alt D+/62/L/DL d = 2 x black to alternator neg. e = split charge diode / relay f = alternator g = starter battery h = domestic battery bank i = red to domestic battery l = temperature sensor to battery ProDigital 1 2 LEAD SEALED GEL GEL OPEN SEALED A.G.M SEALED L.E.D. L.E.D. ( USA) L.E.D. ( YELLOW ) ( GREEN ) ( RED ) LED OFF ON technology ON RoHS compliant ON BATTERY TYPE PROGRAM SELECTOR SWITCH, INSIDE LID 4 BATTERY TYPE POSITIONS UNIVERSAL ADVANCED DIGITAL 4 STEP ALTERNATOR REGULATOR Sterling Power Products Please read and understand the installation instructions before use 12 Volt Alt Model Only RED: High battery voltage trip FLASHING:High battery temp trip ALL LEDS FLASHING: High alt V Yellow: Low voltage warning GREEN :Float mode YELLOW : Timer activated GREEN: High charge rate on GREEN FLASH : Ramp start www.sterling-power.com B Pro Reg b g i e a = gelb an Zündung+ oder (D+/R/L/DL) b = weiss = Feld c = braun an D+/62/L/DL d = 2 x schwarz an Lima negativ-minus e = Trenndiode oder Relais f = Lichtmaschine g = Starterbatterie h = Verbraucherbatteriebank i = rot an plus der Referenzbatterie l = Temperatursensor der Referenzbatterie d POS(+) Temperature-Sensor c j Fig 4 POS(+) f h l INSTALLATON WITH SPLIT CHARGE DIODE OR RELAY: Temperaturesensor INSTALLATON MIT TRENNDIODE ODER RELAIS: ON