Download Type SHC
Transcript
dedicated configuration file that customer may upload to the SHC within his production process. In general, the pre-configuration is done at Honeywell and is based on the customer’s data supplied in the application data questionnaire. Application Data (Questionnaire) Honeywell provides a special questionnaire (.XLS file) to collect customer-specific and application-specific data in a single file. The customer fills out the questionnaire with his application data, supported by Honeywell. Based on this data, Honeywell performs the valve sizing and the pre-calculation of PID parameters as well as the parameter setting to the SHC. Configuration Process Fig. 16. Circuit in reverse mode Reverse operation is handled by an appliance controller – reverse state of circuit is signaled by the appliance controller to the SHC (using SHC digital input) List of Reversing Procedure Parameters Parameter Reversing enabler Reversing valve runtime Value / Range reversing allowed / reversing not allowed 0.1 ... 1000.0 s CONFIGURATION Basic Configuration (Condition at Delivery) The OEM SHC controller comes with customized configuration settings according to the application data provided by customer upfront via SHC Questionnaire (XLS File). At first-time delivery, the SHC is always a functioning sample (OS# SHC-X9999) with basic pre-settings according to the application. This controller should be tested in the dedicated application to enable SHC learning the specific MSS and to enable parameter fine-tuning before creation of a serial configuration including learned MSS characteristic. This may lead to a new (customer- and application-specific) OS# or to a Following the Honeywell standard sample order process, the SHC sample is created manually and shipped to customer accordingly. In order to allow parameter fine tuning from the very beginning and to assure that the SHC achieves optimal performance, the installation at the customer site should be supported by Honeywell-trained specialists. The customer will not have any tool to make parameter settings on his own. Rather, he will be provided only with a configuration tool enabling him to read out the current configuration from SHC and to store it to a file on his computer as well as to upload a configuration file from his PC to the SHC controller. Initial Configuration The initial configuration performed at Honeywell can be identified by order number and by sample request number (specification number). Re-Configuration Any re-configuration or change in configuration should be done in accordance with Honeywell to assure proper documentation of complete settings. For any different type of application, a new pre-configuration should be performed, even for just different size of application within the same series. In case of any lack of security, please contact Honeywell. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Hardhofweg 74821 Mosbach / Germany Phone: (49) 62 61 / 81-475 Fax: (49) 62 61 / 81-461 E-mail: cooling-mosbach@honeywell.com http://www.honeywell-cooling.com Subject to change without notice. Printed in Germany MU2B-0380GE51 R0113