Download DE - Schneider
Transcript
UNM / CPM GB squeezing or hardening. 3. Clean seat, replace complete check valve if damaged. 2.6.12 Replacing the safety valve 1. Detach the safety valve (item 11) by unscrewing it anticlockwise. 2. Apply Loctite® 243 to the thread of the new safety valve or wind Teflon tape around the valve. 3. Screw the new safety valve into place by screwing it clockwise. 3. Drain the condensate, depressurise the compressor. 4. Prior to returning to operation, replace corrosion inhibiting oil with compressor oil. Store the compressor in a dust-free and dry area where it is not exposed to high temperature fluctuations. 2.7.2 Disposal 2.7 Decommissioning Do not throw the tool in your household waste!! Dispose of machines, accessories and packaging at an environmentally responsible recycling centre. Observe the valid national regulations. EU only: European Directive 2002/96/EC stipulates that used electric tools must be collected separately and disposed of at an environmentally responsible recycling centre. 2.7.1 Preservation Oil-lubricated compressors: compressor is taken out of service for a long period (over 6 months) or is new from the factory and will not be operated until much later. 1. Replace oil with corrosion inhibitor oil (viscosity SAE 30). See Chap. 2.6.7. 2. Allow the compressor to warm up, switch it off, disconnect the power supply. Do not throw in the household waste. 2.8 Troubleshooting Problem A B C D Cause Remedy Protective motor In case of malfunctions (e.g. X Switch off the compressor. Wait switch interrupts overheating; low voltage; a short while. Actuate the protecpower supply extension cable too long or tive motor switch is available. with incorrect cross-section), Switch on the compressor. the protective motor switch is Protective motor switch trips tripped. again: switch off compressor. Disconnect the power supply. Contact the service partner Pressure relief does Power failure / undervoltage in X Switch off the compressor. It denot function mains with compressor pressurises. Switch on the comswitched on pressor Compressor does Vessel pressure is higher than X Relieve pressure in the vessel not start when switch-on pressure. until the pressure switch is actiswitched on. vated automatically. Power supply faulty. X Have the power supply checked by a qualified person (service partner). Protective motor switch inter- X See item A. rupts power supply. Pressure switch defective X Have the pressure switch changed by a qualified person. Compressor starts Mains connection cable longer X Check connection cable length up briefly / buzzes than permitted or the cross and cable cross-section (see and then switches section is too small Chap. 2.4.4) off automatically II/11