Download DE - Schneider

Transcript
UNM / CPM
GB
squeezing or hardening.
3. Clean seat, replace complete check valve
if damaged.
2.6.12 Replacing the safety valve
1. Detach the safety valve (item 11) by unscrewing it anticlockwise.
2. Apply Loctite® 243 to the thread of the
new safety valve or wind Teflon tape
around the valve.
3. Screw the new safety valve into place by
screwing it clockwise.
3. Drain the condensate, depressurise the
compressor.
4. Prior to returning to operation, replace
corrosion inhibiting oil with compressor
oil.
Store the compressor in a dust-free and dry
area where it is not exposed to high temperature fluctuations.
2.7.2 Disposal
2.7 Decommissioning
Do not throw the tool in your household
waste!! Dispose of machines, accessories
and packaging at an environmentally responsible recycling centre. Observe the valid
national regulations.
EU only: European Directive 2002/96/EC
stipulates that used electric tools must be
collected separately and disposed of at an
environmentally responsible recycling centre.
2.7.1 Preservation
Oil-lubricated compressors: compressor is
taken out of service for a long period (over 6
months) or is new from the factory and will
not be operated until much later.
1. Replace oil with corrosion inhibitor oil
(viscosity SAE 30). See Chap. 2.6.7.
2. Allow the compressor to warm up, switch
it off, disconnect the power supply.
Do not throw in the household waste.
2.8 Troubleshooting
Problem
A
B
C
D
Cause
Remedy
Protective
motor In case of malfunctions (e.g. X Switch off the compressor. Wait
switch
interrupts overheating;
low
voltage; a short while. Actuate the protecpower supply
extension cable too long or tive motor switch is available.
with incorrect cross-section), Switch on the compressor.
the protective motor switch is Protective motor switch trips
tripped.
again: switch off compressor.
Disconnect the power supply.
Contact the service partner
Pressure relief does Power failure / undervoltage in X Switch off the compressor. It denot function
mains
with
compressor pressurises. Switch on the comswitched on
pressor
Compressor
does Vessel pressure is higher than X Relieve pressure in the vessel
not
start
when switch-on pressure.
until the pressure switch is actiswitched on.
vated automatically.
Power supply faulty.
X Have the power supply checked
by a qualified person (service
partner).
Protective motor switch inter- X See item A.
rupts power supply.
Pressure switch defective
X Have
the
pressure
switch
changed by a qualified person.
Compressor starts Mains connection cable longer X Check connection cable length
up briefly / buzzes than permitted or the cross and cable cross-section (see
and then switches section is too small
Chap. 2.4.4)
off automatically
II/11