Download INSTRUCTIONS FOR USE
Transcript
!ـ ــــــت اام
INSTRUCTIONS FOR USE
OPERATION
" و+&B1
د1 57,)& ز+,& ا@لo? آ م
.ز+,& ا$1ق ا7)1n
ا1 "t 3 "+:?)ا
ز+,&" ا+&و7 رB3 ت,a& أو اJa&?ت ا% $ آn •
. وق ا&?ودة5?6 ا& أنo
اام
qP& ا$3 ا،KX7 ! أوA مP& ا$?# •
.N+& اAE-)&? اr $3< أو اN+& ا&)ر اE1
ZAزB وJa& اZ =ة ا&=ودة+C ا$ آ$!B 5,A •
ً
ً ? ء ر/ ا&ء
o) TP3 ب/& e&!
ءا
MPa 0.81 و0.17 ? ا&ءr T-L S)A
أو/ وJa& اZ! ء$ إدة5,A .(bar 1.8 و1.7)
ءr? $/ ? ء/ ) -&ز< ا&ء اB
.TP3 ب/& &!
A ىB)6& دل%& ا$!اB)&ع اB6& اT-S&ى اB)6 • إن
" .(A) $?6A د70 $# اb?A <& اJa&?ت ا% Z&
ز و+,&
ا: ) وا% H ت:P& اE1أ
.)جvء دورة آ ا7t أ، ) ارع ارض1.60
امF%
م ا% + < 'IS +آ
ا!
آF; ا
ً
.3
آ'رةWدات اKرXا <ت و ا
Z آFا
.ارةe& ب رP& ز+,&د اBCآ م و
?,& آ ا36 اك،N AB+ نS&
.5ت ا&)آ% Z?ز و ا+,& يB%&=ء ا,&و ا
.ز+,& AB+)&ت اe)3 W- n
.ز+,& اA? دورة5 أK) n
L أرH %Lى وB)6 T?L ز و+,& ا5" )آ#
.اG): و اfد% N <3 زن وB& ا$e)
ز+,& " إاد ا.AB+)&ة اC و3C <3 ز+,& اZL
ً
P?@
!&" اP&ارة اe& اC درS) < ت3 $%&
ا& م.$,6)& اeNn H اردةB& اAB,&&ت ا
ارةC< در3 AB@ < & آ &)ة3 ز+,& ا$
.دةe& ا&ة ا$# و أHأ
•
•
•
•
•
•
Operation is fully automatic. Ice formation is obtained
through gradual freezing of a layer of water that runs
on the tilted freezing plate. 4).
When the desired thickness is reached, a thermostat
automatically activates to detach the ice slab , which
slides on the low voltage elements (Fig. 5). The slab is
then cut into cubes, which are collected in the
container below. The production cycle continues until
the container is full: a limit thermostat will
automatically deactivate the ice production unit.
When, after a certain amount of ice cubes have been
used, or due to them melting, their quantity falls below
a certain level, the same thermostat will reactivate ice
production (therefore the unit can always be left on,
even when not being used). Any residual water leaves
the appliance through the discharge pipe.
I ارة اF% Pدر
(EC<>F<+ )
I ارة اF% Pدر
(
C'I P) در
90 H& إ50 32 H& إ10 SN
STARTUP
90 H& إ61 32 H& إ16 N
100 H& إ61 38 H& إ16 ST
It is recommended that the appliance is thoroughly
cleaned before being switched on. Follow the cleaning
instruction on the “Maintenance” section.
- Insert the plug in the electric socket.
- Open the water tap.
- Press the green switch.
110 H& إ61 43 H& إ16 C'#
اIا
T
+,& P
$,6)& اeNn H 8&B& ا# آ أن
."&=7 <+&ا
.&@دة أو و! ت إ%) أوAد3 تnBe مG)6 n
A,&ز ا+,& W3&ب اB?م اG): ا،? ا&ء/ $!B)&
."AP&ز ا+,&ب اB?ام أG): ا% n و
$?# N+& اAE-)& اO: )?ال: أو ا- ")A أن5,A
.TP3 $هm MGr
qP& ا$ اءB: <N+& ا&)ر اZ
# ")A ا& أن
H ZLBA 5
P&< اN7t ?/& ر اZ@# WA@ أو
.qP&ا
•
•
•
•
اEت ه%)& ا5) آZ P3& اJa& اZ, < وة3 ,
3& ،f& اbA بB? أ،f& AE-)&? ا/ $!B)&ب اB?أ
•
-! بB? Z# ،Ja&زا& اv ة-! 3, H يB)e
و6 Z ،T?S& # $C أر% أر،A ا&ور3X7&
.% اص#أ
A< زوا3 G&" ا+< أ3 8?a)&ام ا# أ5" )آ# :<A %?) ةP&ا
نMا
ةP&=ء ا< ا,& اH ووظP& ا&ت اK& ل%)r & # ادB ز أوw ،A=7 مG)6 ) أوe n •
ا&تH ?&B& T?S& P& ا$C ارK& آ وe)&ا
a%?7&ة اG ا.ى1=& أ7 =ة+Cز أو أ+,&ب اP&
.(1 $r ) +6
.ر, و اWA 5?6 ا& أن
H& ا إ$C ارT?S "# ،8t : H ز+,& اZLB
اع:& N أو آN+ آ، م أدواتG)6 n •
H ز+,& ا5" )آP n .ازنB) ZL وH لBe&)" اA أن
،$1 أو ا&اTNاBe&ت اAB, <3 ،ارةe& در اP 7A )G نB& اJa& اMG)& ا
.Z7&ا
$?#
? اءB+&ق آ دوران اB% # <)&ران ا,&ب اP& أو
ِ
6 ز+,&ذاة اe $P أن5,A n ) ز+,& اAB+ ?تr "& ز إن+,&م ا6# N+=ات آ+, $1 م أوG)6 n •
.Z7& ا$?# )%&ع اB7& اq اBBA
.(":
$!B)&< أآ ا3 f& اbA ل وB1ب دB? أ$!B) "# - ) صGr ا$?# ل%): & MG w ز+,&ا اE• ه
أو6e& أو ا6,&رات اP& ا@ل( ذوي اO&< ذ3
ز+,&ار اC H دةBCB&ت اe)& اWA@ G&ا
nإ،ز+,& 3%&أو ا/ ?ة وG&< ا# أو، ودةe& اP%&ا
.(2 $r ) <G&ا
MGr $?# امG):nء ا7t" أ+)?#ده" أو اr< & إر3
."+) : لB6
ICE THICKNESS ADJUSTMENT
The thickness thermostat is adjusted at the
manufacturer for optimum ice cube thickness. This
thickness can be changed turning the thermostat knob
with a coin. Turn clockwise to increase thickness and
anticlockwise to decrease (Fig. 6).
The thermostat knob can also be used to regulate the
appliance based on environmental temperature
variations, above 32°C or below 10°C.
- Never rotate the thermostat knob outside the
indicated range.
- Only adjust ice thickness after the unit has been in
operation for a few hours (the ice cube container
must be at leas half full).
- A wrong adjustment of the thickness thermostat
may jeopardise the operation of the appliance. If,
due to high environmental temperature, the
thermostat knob is set to a too high maximum
value, the thickness of the ice will be such that the
ice slab cannot be detached. Vice versa, if the
thermostat is set to too low a value, thickness will
be greatly reduced, and ice production may not be
possible.
ADJUSTING THE ICE LEVEL ON THE
CONTAINER
The container level thermostat is set by the
manufacturer to the optimum average position.
However, if the environment temperature rises above
32° C, it will be necessary to move the thermostat to
the
position. With temperatures below 16° C, it
will be necessary to rotate the index to the
position (Fig. 7).
The quantity of ice that can be produced by this
appliance over a 24-hour period also depends on the
model purchased:
PGK20 24 Kg/24 h
PGK40 40 Kg/24 h
(the shown values are for models intended for climate
class “N”).
MAINTENANCE
Do not clean the appliance with running water. Before
carrying out any cleaning operations, disconnect the
appliance from the power supply, and close the water
supply tap.
It is recommended that the appliance is cleaned every
so often (at least every six month), and that the water
system in particular is cleaned regularly.
The frequency of cleaning depends on the hardness of
the water: with time, limscale will form on the
refrigerating plate and inside the tank, preventing the
appliance from working correctly. In this case, it will be
necessary to clean the water system more often. To
clean the water system, proceed as follows:
1. Close the water supply tap and press the green
button to switch the appliance off.
2. Empty the ice tube container.
3. Remove the cap or the output pipe (where fitted)
inside the cell (Fig. 8) to empty the tank.
4. Use the funnel, connected to the draining outlet
through the tube, to fill the tank (Fig. 9) with
approximately 1.5 litres of water mixed with 1
decilitre of vinegar, or 4 spoons of lemon juice, or
citric acid.
5. Press the two switches (green and blue) and
operate the appliance for about 40 minutes.
6. Release the two switches (green and blue) and
drain the cleaning solution from the tank cell by
turning the funnel.
7. Fill the tank with a mix of 1.5 litres of water and
two spoonfuls of bicarbonate. Press the two
switches (green and blue) and operate for about 5
minutes.
8. Empty as above, and refill again, this time using 1.5
litres of pure water, operating the appliance for 5
minutes to rinse.
9. Remove the funnel with the discharge pipe and
replace the cap or the output pipe on the
discharge outlet.
10. Clean the inside of the ice container and the door
seal using a cloth and some water mixed with
bicarbonate.
11. Press the green switch and open the water supply
tap: ice cube production will commence
immediately.
This document in other languages
- français: Whirlpool AGH 326/01/G
- español: Whirlpool AGH 326/01/G
- Deutsch: Whirlpool AGH 326/01/G
- Nederlands: Whirlpool AGH 326/01/G
- dansk: Whirlpool AGH 326/01/G
- svenska: Whirlpool AGH 326/01/G
- italiano: Whirlpool AGH 326/01/G
- suomi: Whirlpool AGH 326/01/G