Download Instruction Manual

Transcript
TANK
6
EN
CHILLER LINE
MANTAINANCE
6.1
ROUTINE MAINTENANCE
The device does not require any routine maintenance.
7
DIAGNOSTICS, PROBLEMS, CAUSES AND REMEDIES
7.1
Disadvantages, causes and remedies table
Disadvantages
Causes
The display does not Lack of electric suplight up.
ply.
Insufficient water flow.
Aquarium isolation is
not enough.
Dirty air filter.
Insufficient
cooling.
water
Ambient temperature
too high.
Outgoing air from the
ventilation grid at room
temperature.
Ventilation
system
clogged.
Broken
ventilation
system.
Remedies
Check if the plug (Rif. A4 Fig. 4) is correctly inserted into the
device.
Make sure that the plug is fully inserted into the power outlet
(Rif. A5 Fig. 4).
Check if the fuse is not burned. (C1 Fig. 4).
Check the proper operation of the pump (not supplied) (Rif.
A1 Fig. 12-13).
Insulate the walls of the aquarium and the pipes to reduce
heat loss.
Clean the air filter following the instruction (Chapter 6 Maintenance).
Re-establish the optimal ambient conditions.
The maximum ambient temperature allowed is 38°C (100°F).
Lack of gas in the compressor, contact the TECO S.r.l area
retailer.
Free up or clean the metal grid or place the chiller in an appropriate environment .
Contact the TECO S.r.l area retailer.
Check the correct operation of the pump (not supplied) (Rif.
water Insufficient water flow. A1 Fig. 12-13).
Faulty heater.
Contact the TECO S.r.l area retailer.
On the display apDamage of the water’s
pears the message
Contact the TECO S.r.l area retailer.
temperature probe.
“P1”.
The water does not cir- Check eventually pipes obstructions.
culate correctly inside
Check the efficiency of the aquarium’s pump (not supplied).
the hydraulic circuit.
The temperature disLong and not insulated
played is not the real
Reduce as much as possible the pipes and insulate them.
pipes.
one.
Temperature sensor
Calibrate the temperature sensor as described in paragraph
not calibrated cor5.2.2 Thermostat Settings.
rectly.
Tab. 7-1
Insufficient
heating.
WARNING: Before you unplug the machine from the pipes it is necessary to turn off the device
and unplug all electrical plugs from the equipment connected to the aquarium.
Close also the pipes to prevent water leakage.
12