Download Installation Manual
Transcript
SAFETY INSTRUCTIONS CAUTION WARNING Attach securely protective earth to the ship's body. Hazardous voltage. Can shock, burn or cause serious injury. The protective earth (grounding) is required to the AC/DC power supply unit to prevent electrical shock. Do not work inside the equipment unless totally familiar with electrical circuits. Do not approach the antenna closer than 0.9 m (MPE by FCC) when it is transmitting. Confirm that the power supply voltage is compatible with the voltage rating of the equipment. The antenna emits radio waves which can be harmful to the human body. Connection to the wrong power supply can cause fire or equipment damage. The voltage rating appears on the label at the rear of the display unit. RF power density Description Distance on antenna aperture required by 100 W/m FM-8800S FM-8800D 2 10 W/m 2 W/m 2 100 W/m 2 0.11 m IEC 60945 0.33 m IEC 60945 0.9 m MPE by FCC 0.11 m IEC 60945 10 W/m 2 2 W/m 2 0.33 m IEC 60945 0.9 m MPE by FCC 2 (MPE: Minimum Permissible Exposure) Turn off the power at the mains switchboard before beginning the installation. Post a warning sign near the switchboard to indicate that power should not be applied while the equipment is being installed. Electrical shock, serious injury or fire can result if the power is not turned off or is applied while the equipment is being installed. Observe the compass safe distance to prevent deviation of a magnetic compass. Standard compass Steering compass FM-8800S 1.45 m 0.90 m FM-8800D 1.45 m 0.95 m IF-8810 0.85 m 0.55 m IF-8820 0.75 m 0.50 m HS-2003 1.50 m 0.95 m HS-8800 0.40 m 0.30 m RB-8800 (W/HS-8800) 1.20 m 0.80 m 1.50 m 1.00 m 0.90 m 0.60 m RB-8810 (W/HS-8800) PR-240-CE i