Download Mode d`emploi
Transcript
Plage Achage Précision d'affichage Précision 32.0°C~42.9°C (89.6°F~109.2°F) Achage à cristaux liquides, 3 1/2 digits 0.1ºC or 0.2ºF ±0.1°C 35.5°C~42.0°C (±0.2°F 95.9°F~107.6°F) ±0.2°C en dessous de 35.5°C ou au-dessus de 42.0°C (±0.4°F en dessous de 95.9°F ou au-dessus de 107.6°F) à la température ambiante standard de 25.0°C (77.0°F). Speicher Zur Speicherung des letzten Messwertes Pile Une pile bouton 1.5 Vcc (SR41 ou LR41) Durée de vie de la pile Environ 1500 mesures consécutives ou 1 an à raison d‘une à deux mesures par jour, mode veille compris. Dimensions 12.2x2.0x1.1cm (L x l x h) Poids Environ 9.5 grammes avec la pile Alarme Signal sonore d‘environ 10 secondes une fois le pic de température atteint Environnement Température: 5°C~40°C (41°F~104°F) d‘utilisation Humidité: ≤95% RH. Conditions de stockage Température: -25.0°C ~ 55.0°C (-13.0°F ~ 131.0°F), et de transport Humidité: ≤95% RH Accessoires pile, étui de transport, mode d‘emploi Classe de sécurité Type B Pièce appliquée Informations CEM et déclaration du fabricant Guidance and manufacturer’s declaration-electromagnetic emissions The TG120 is intended for use in the electromagnetic environment specified below. The customer or the user of the TG120 should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance RF emissions CISPR 11 Group 1 The TG120 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Class B Harmonic emissions Not applicable IEC 61000-3-2 Voltage fluctuations/flicker Not applicable emissions IEC 61000-3-3 The TG120 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Guidance and manufacturer’s declaration-electromagnetic immunity The TG120 is intended for use in the electromagnetic environment specified below. The customer or the user of the TG120 should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance Electromagnetic environment-guidance level Electro+ 6 kV contact + 6 kV contact Floors should be wood, concrete or ceramic static discharge(ESD) tile. If floors are covered with synthetic mateIEC61000-4-2 + 8 kV air + 8 kV air rial, the relative humidity should be at least 30% Electrical fast transient/ + 2kV for power Not applicable Mains power quality should be that of a typical burst IEC61000-4-4 supply lines commercial or hospital environment. + 1kV for input/ Not applicable output lines Surge IEC 61000-4-5 + 1kV line(s) to Not applicable Mains power quality should be that of a typical line(s) commercial or hospital environment. + 2kV line(s) to Not applicable earth Voltage Dips, short in- <5% UT(>95% Not applicable Mains power quality should be that of a typical terruptions and voltage dip in UT) for 0,5 commercial or hospital environment. If the variations on power cycle user of the TG120 requires continued operation supply input lines IEC 40% UT(60% dip Not applicable during power mains interruptions, it is recom61000-4-11 in UT) for 5 cycles mended that the TG120 be powered from an 70% UT(30% dip Not applicable uninterruptible power supply or a battery. in UT) for 25 cycles <5% UT(>95% Not applicable dip in UT) for 5 s P o w e r f r e q u e n c y 3 A/m 3 A/m The TG120 power frequency magnetic fields (50/60 Hz) magnetic should be at levels characteristic of a typical field IEC 61000-4-8 location in a typical commercial or hospital environment. NOTE UT is the a.c. mains voltage prior to application of the test level. Guidance and manufacturer’s declaration-electromagnetic immunity The TG120 is intended for use in the electromagnetic environment specified below. The customer or the user of the TG120 should assure that is used in such and environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance Conducted RF 3 Vrms Not applicable Portable and mobile RF communications IEC 61000-4-6 150 KHz to 80 MHz equipment should be used no closer to any part of Radiated RF 3 V/m 3 V/m the TG120 including cables, than the IEC 61000-4-3 80MHz to 2,5 GHz recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance: d = 1,2 √P d = 1,2 √P 80MHz to 800 MHz d = 2,3 √P 800MHz to 2,5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey. a. Should be less than the compliance level in each frequency range. b. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the TG120 is used exceeds the applicable RF compliance level above, the TG120 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the TG120. b. Over the frequency range 150 kHz to 80 MHz, field strengths should be les than 3 V/m. GARANTIE Recommended separation distance between portable and mobile RF communications equipment and the TG120 The TG120 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the TG120 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the TG120 as recommended below, according to the maximum output power of the communications equipment. Rated maximum output Separation distance according to frequency of transmitter m power of transmitter W 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d =1,2√P d =1,2√P d =2,3√P 0,01 N/A 0,12 0,23 0,1 N/A 0,38 0,73 1 N/A 1.2 2.3 10 N/A 3.8 7.3 100 N/A 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P The maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Achat pour: Cet instrument est garanti pendant 5 ans à partir de la date d‘achat. Les piles et les accessoires ne sont pas couverts par la garantie. La garantie n‘est valide que sur présentation par l‘acheteur de la preuve d‘achat ou de la carte de garantie complétée par le vendeur, confirmant la date d‘achat. Le fait d‘ouvrir ou de modifier l‘appareil annule le droit à la garantie. La garantie ne couvre pas les dommages, accidents ou le non-respect des instructions contenues dans le manuel. Veuillez contacter le service après-vente Rossmax. Information produit Date d’achat: Point de vente où l’appareil a été acheté: Prix payé (hors taxe): Rossmax International Ltd. 12F., No. 189, Kang Chien Rd., Taipei, 114, Taiwan. Rossmax Swiss GmbH, Tramstrasse 16, CH-9442 Berneck, Switzerland OBM_IB_TG120Q_FR_ver1303 IN0TG12000000000XXXXXXX SPÉCIFICATIONS www.qutie-rossmax.com