Format des données MIDI
4.8 Function call – Channe –
4.9
4.8.1
4.9.1 Format (Parameter change)
When transmission is enabled by receiving Request for Level Meter, the
corresponding metering data will be sent in every 50 millisecond for 10 seconds.
If metering information is expected to be continuously sent, Request is needed
to be sent in at least every 10 seconds.
Pair ON/OFF Trigger Format (Parameter change)
Receive
Data will be received when [Parameter change Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[Parameter change ECHO] is on.
11110000
01000011
0001nnnn
00111110
00010001
00000000
System exclusive message
Manufacture’s ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
M7CL
OTHER DATA
01000011 "C"
01101000
01101100
01010000
01101001
01110010
01000011
01110000
MODULE NAME 0mmmmmmm
0mmmmmmm
0mmmmmmm
0mmmmmmm
0mmmmmmm
0mmmmmmm
0mmmmmmm
0mmmmmmm
DATA
0sssssss
0sssssss
0ddddddd
0ddddddd
EOX
11110111
4.8.2
F0
43
1n
3E
11
00
"h"
"l"
"P"
"i"
"r"
"C"
"p"
mm (ASCII CODE)
mm (ASCII CODE)
mm (ASCII CODE)
mm (ASCII CODE)
mm (ASCII CODE)
mm (ASCII CODE)
mm (ASCII CODE)
mm (ASCII CODE)
ss Source Channel Number H *1)
ss Source Channel Number L *1)
dd Destination Channel Number H *1)
dd Destination Channel Number L *1)
F7 End of exclusive
Transmission
When transmission is enabled by receiving Request, the corresponding metering
data will be sent in constant interval for a given period of time (The interval and
time will vary depending on devices). When rebooted or port setting is changed,
the transmission will be disabled.
When [Parameter change ECHO] is on, the message will be sent as it is.
STATUS
ID No.
SUB STATUS
GROUP ID
MODEL ID
DATA
CATEGORY
DATA
EOX
4.9.2
11110000
01000011
0001nnnn
00111110
00010001
00100001
F0
43
1n
3E
11
21
System exclusive message
0mmmmmmm
0mmmmmmm
0mmmmmmm
0ddddddd
:
11110111
mm
mm
mm
dd
:
F7
ADDRESS UL
Manufacture’s ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
M7CL
REMOTE LEVEL METER
ADDRESS LU
ADDRESS LL
Data1
End of exclusive
Format (Parameter request)
Receive
Data will be received when [Parameter change Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[Parameter change ECHO] is on. the corresponding metering data will be sent
via [Rx CH] in constant interval for a given period of time (The interval and
time will vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be
immediately stopped [disabled].
Transmission
When [Parameter change ECHO] is on, the message will be sent as it is.
Module Name
MODULE NAME
Pair On (with Copy)
Pair On (with Reset Both)
Pair Off
Receive
The data will be echoed when [Parameter change ECHO] is ON.
”PAIRONCP”
”PAIRONRS”
”PAIROFF_”
*1) 0:CH1–47:CH48
256:MIX 1– 271:MIX 16
512:MATRIX 1–519:MATRIX 8
STATUS
ID No.
SUB STATUS
GROUP ID
MODEL ID
DATA
CATEGORY
DATA
EOX
11110000
01000011
0011nnnn
00111110
00010001
00100001
F0
43
3n
3E
11
21
System exclusive message
0mmmmmmm
0mmmmmmm
0mmmmmmm
0ccccccc
0ccccccc
11110111
mm
mm
mm
ch
cl
F7
ADDRESS UL
Manufacture’s ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
M7CL
REMOTE LEVEL METER
ADDRESS LU
ADDRESS LL
Count H
Count L
End of exclusive
Annexes
STATUS
ID No.
SUB STATUS
GROUP ID
MODEL ID
DATA
CATEGORY
FUNCTION
NAME
Level Meter Data