Download Notice - Spencer
Transcript
Format des données MIDI 4.8 Function call – Channe – 4.9 4.8.1 4.9.1 Format (Parameter change) When transmission is enabled by receiving Request for Level Meter, the corresponding metering data will be sent in every 50 millisecond for 10 seconds. If metering information is expected to be continuously sent, Request is needed to be sent in at least every 10 seconds. Pair ON/OFF Trigger Format (Parameter change) Receive Data will be received when [Parameter change Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [Parameter change ECHO] is on. 11110000 01000011 0001nnnn 00111110 00010001 00000000 System exclusive message Manufacture’s ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) Digital mixer M7CL OTHER DATA 01000011 "C" 01101000 01101100 01010000 01101001 01110010 01000011 01110000 MODULE NAME 0mmmmmmm 0mmmmmmm 0mmmmmmm 0mmmmmmm 0mmmmmmm 0mmmmmmm 0mmmmmmm 0mmmmmmm DATA 0sssssss 0sssssss 0ddddddd 0ddddddd EOX 11110111 4.8.2 F0 43 1n 3E 11 00 "h" "l" "P" "i" "r" "C" "p" mm (ASCII CODE) mm (ASCII CODE) mm (ASCII CODE) mm (ASCII CODE) mm (ASCII CODE) mm (ASCII CODE) mm (ASCII CODE) mm (ASCII CODE) ss Source Channel Number H *1) ss Source Channel Number L *1) dd Destination Channel Number H *1) dd Destination Channel Number L *1) F7 End of exclusive Transmission When transmission is enabled by receiving Request, the corresponding metering data will be sent in constant interval for a given period of time (The interval and time will vary depending on devices). When rebooted or port setting is changed, the transmission will be disabled. When [Parameter change ECHO] is on, the message will be sent as it is. STATUS ID No. SUB STATUS GROUP ID MODEL ID DATA CATEGORY DATA EOX 4.9.2 11110000 01000011 0001nnnn 00111110 00010001 00100001 F0 43 1n 3E 11 21 System exclusive message 0mmmmmmm 0mmmmmmm 0mmmmmmm 0ddddddd : 11110111 mm mm mm dd : F7 ADDRESS UL Manufacture’s ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) Digital mixer M7CL REMOTE LEVEL METER ADDRESS LU ADDRESS LL Data1 End of exclusive Format (Parameter request) Receive Data will be received when [Parameter change Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [Parameter change ECHO] is on. the corresponding metering data will be sent via [Rx CH] in constant interval for a given period of time (The interval and time will vary depending on devices). When Address UL = 0x7F is received, all metering data transmission will be immediately stopped [disabled]. Transmission When [Parameter change ECHO] is on, the message will be sent as it is. Module Name MODULE NAME Pair On (with Copy) Pair On (with Reset Both) Pair Off Receive The data will be echoed when [Parameter change ECHO] is ON. ”PAIRONCP” ”PAIRONRS” ”PAIROFF_” *1) 0:CH1–47:CH48 256:MIX 1– 271:MIX 16 512:MATRIX 1–519:MATRIX 8 STATUS ID No. SUB STATUS GROUP ID MODEL ID DATA CATEGORY DATA EOX 11110000 01000011 0011nnnn 00111110 00010001 00100001 F0 43 3n 3E 11 21 System exclusive message 0mmmmmmm 0mmmmmmm 0mmmmmmm 0ccccccc 0ccccccc 11110111 mm mm mm ch cl F7 ADDRESS UL Manufacture’s ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) Digital mixer M7CL REMOTE LEVEL METER ADDRESS LU ADDRESS LL Count H Count L End of exclusive Annexes STATUS ID No. SUB STATUS GROUP ID MODEL ID DATA CATEGORY FUNCTION NAME Level Meter Data Mode d'emploi de M7CL 261