Download Operator Manual - Air
Transcript
MAINTENANCE/PARTS Problem Cause / Solution Note: To avoid performance deterioration of the Powermax900, input voltage should be within 10% of the specified system line voltage setting. System Lower Limit Line Voltage Upper Limit 164VAC 200VAC 235VAC 170VAC 208VAC 239VAC 189VAC 230VAC 270VAC 197VAC 240VAC 276VAC 328VAC 400VAC 470VAC 393VAC 480VAC 552VAC 510VAC 600VAC 690VAC 3b. The POWER ON LED is illuminated, the LINE VOLTAGE LED is blinking yellow and the torch is disabled. 3b.1 Power supply voltage links are incorrect. See voltage configuration settings in Section 3. 3b.2 Line voltage is too low. Line voltage is less than 20% of nominal. Have an electrical technician check incoming power. 3c. The POWER ON LED is illuminated, the LINE VOLTAGE LED is continuous yellow and the torch is working. 3c.1 Power supply voltage links are incorrect. See voltage configuration settings in Section 3. 3c.2 Line voltage is too low. Line voltage is between 15% and 20% below nominal. Have an electrical technician check incoming power. 3d. The LINE VOLTAGE LED is continuous red, power supply is disabled. 3d.1 Line voltage is too high. LIne voltage is greater than 15% of nominal. Have an electrical technician check incoming power. 3d.2 Torch cap is not engaging microswitch. Verify that the torch consumables are installed correctly and that a "click" is heard when the retaining cap is screwed down. 3d.3 Trip circuit is defective. See Technical Questions on page 5-7. 3d.4 There is a control board failure. Turn power supply off and then on. If problem persists, see Technical Questions on page 5-7. Operator Manual 5-5 9-99