In addition, NSF International has verified the water treatment claims for this model for the reduction of specific substances which are not included in NSF/ANSI Standard 53 or Standard 42 as follows: Additional Contaminants Additional Contaminants EPA Priority Pollutants Chemical % Reduction Influent Concentration Effluent (µg/L) Concentration (µg/l) EPA Priority Pollutants Acenaphthene Acenaphthylene Aldrin Anthracene Benzidine Benzo[a]anthracene Benzo[a]pyrene Benzo[b]fluoranthene Benzo[g,h,i]perylene Benzo[k]fluoranthene alpha-BHC beta-BHC delta-BHC gamma-BHC Bis(2-Chloroethoxy) methane Bis(2-chloroethyl) ether Bis(2-chloroisopropyl) ether Bis(2-ethyl-hexyl) phthalate 4-Bromophenyl phenyl ether Butyl benzyl phthalate 4-Chloro-3-methylphenol 2-Chloroethyl vinyl ether 2-Chlorophenol 4-Chlorophenyl phenyl ether Chrysene 4,4’-DDD Di-n-butyl phthalate Di-n-octyl phthalate Dibenzo[a,h]anthracene 1,3-Dichlorobenzene 3,3’-Dichlorobenzidine 2,4-Dichlorophenol trans-1,3-Dichloropropene Dieldrin Diethyl phthalate Dimethyl phthalate 2,4-Dimethylphenol 4,6-Dinitro-2-methyl phenol 2,4-Dinitrotoluene 2,6-Dinitrotoluene 1,2-Diphenylhydrazine alpha-Endosulfan beta-Endosulfan Endosulfan Sulfate Endrin Aldehyde Fluoranthene Fluorene Hexachlorobenzene Hexachloroethane Isophorone Naphthalene Nitrobenzene 2-Nitrophenol 4-Nitrophenol N-Nitroso-di-n-propylamine N-Nitrosodiphenylamine PCB-1016 PCB-1221 >99.7 >99.7 97.4 >99.6 >99.6 >99.3 92.5 98.7 91.0 98.1 >99.6 >99.6 >99.6 >99.6 >99.3 >99.0 >98.3 99.0 >99.1 >99.4 >99.1 >99.9 >98.1 >99.1 >97.8 97 >99.6 >98.8 93.4 >99.8 >99.6 >98.7 >99.9 99.7 >99.7 >99.8 >98.7 >99.3 >94.3 >95.1 >99.0 97.1 97.5 95.4 >99.0 >98.2 >99.7 >98.8 >96.6 >98.4 >99.7 >98.5 >99.5 >99.8 >99.2 >99.1 >98.8 >99.6 67.9 44.9 14.4 0.0106 2.54 0.224 0.0605 0.316 0.434 0.325 80.6 81.4 77.8 80.9 136 213 206 199 225 226 171 298 175 197 0.232 59.4 245 179 0.524 99.7 4.89 161 163 132 202 197 167 57.4 175 204 161 75.6 79.4 85.2 20.3 0.303 7.56 84.3 46.6 177 23.4 156 150 57.6 157 147 57.9 49.7 <DL <DL 0.38 <DL <DL <DL 0.00456 0.00416 0.0390 0.00611 <DL <DL <DL <DL <DL <DL <DL 2 <DL <DL <DL <DL <DL <DL <DL 1.7 <DL <DL 0.0345 <DL <DL <DL <DL 0.43 <DL <DL <DL <DL <DL <DL <DL 2.20 1.95 3.95 <DL <DL <DL <DL <DL <DL <DL <DL <DL <DL <DL <DL <DL <DL Chemical % Reduction PCB-1232 PCB-1242 PCB-1248 PCB-1254 Phenanthrene Phenol Pyrene Strychnine TCDD 2,3,7,8Tetrachlorodibenzoparadioxin TCDF 2,3,7,8Tetrachlorodibenzofuran 2,4,6-Trichlorophenol 1,2,3-Trichloropropane Vinyl Chloride Influent Concentration Effluent (µg/L) Concentration (µg/l) >98.4 >99.2 >99.4 >97.5 >99.0 >98.1 >98.1 >99.8 30.9 35.5 35.6 40.3 0.0752 68.7 0.328 47.5 <DL <DL <DL <DL <DL <DL <DL <DL >99.9 0.0131 <DL >99.9 >98.7 >99.4 >93.9 0.0269 168 86.8 8.2 <DL <DL <DL <0.5 Non-EPA Priority Pollutant Aldicarb Carbaryl Chlorpyrifos 4,4’-Dibromo-1,1’-biphenyl Guthion Hydrocarbons Malathion Parathion 99.8 >98.3 >99.9 95.7 >99.9 >91.3 >99.0 99.9 103 511 212 46.0 46.1 1150 217 212 0.21 <DL <DL 2.00 <DL <DL <DL <DL Rated Flow Speed: 0.9 gallons per minute (3.4 L/min) Capacity of Filter: 1320 gallons (5000 L) or one year service Maximum Working Pressure: 125 psi (862 kPa) Minimum Pressure: 15 psi (103.5 kPa) Maximum Water Temperature: 86° F (30° C) Minimum Water Temperature: 40º F (4.4º C) Electrical Requirements: Four (4) AA Alkaline Batteries General Installation Conditions and Needs: See Owner’s Manual General Operation and Maintenance Requirements: See Owner’s Manual Explanation of Performance Indicator: See Owner’s Manual Manufacturer’s Limited Warranty: See Owner’s Manual Installation must comply with local, regional, or national laws and regulations. The contaminants listed above for reduction by the eSpring® Carbon Water Treatment System are not necessarily in your water. The Carbon Water Treatment System has been certified for the reduction of radon from drinking water at a loading rate of four gallons (15 liters) per day. The certification is not for other potential radon sources including air. The system should not be used on drinking water containing radon levels in excess of 4000 pCi/L. While testing of this system was performed under standard laboratory conditions, your actual performance may vary. CAUTION: Do not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Product Information Number: In the United States, call 1-800-253-6500 M-F 8 AM – 12 AM and Sat. 8:30 AM – 5 PM. System Tested and Certified against NSF/ANSI Standard 42, 53 and CSA B483.1. In Canada, call 1-800-265-5470 M-F 8 AM – 12 AM and Sat. 8:30 AM – 5 PM. Manufactured by Access Business Group LLC, Ada, MI 49355 U.S.A. ® /trademark licensed by Alticor, © 2010, Alticor 1024456