Download Manuel d`Installation
Transcript
INSTALLATION MANUAL FOR ROOM Installation Parts AIR CONDITIONER Name of part Remote control Battery Tapping screw ST4.2x25 Drainage pipe Air filter Wall-mounting plate Rubber cushion Part no. 1 2 3 (Split Wall Mounted Type) 4 5 6 • To ensure proper installation, read this manual before starting. • Installation, repair and servicing of the air conditioner should be done only by trained and qualified personnel and not by end users themselves. • The air conditioner that you purchased may be slightly different than the illustrations in this manual which are only drawings. 7 Qty 1 2 5 1 2 1 4 TIPS ON REMOTE CONTROL OPERATION • Before installation, operate the remote control to determine its range. • Keep the remote control at least 1 m from the nearest television set or stereo system. • Do not place the remote control in a location that is exposed to direct sunlight or that is close to a source of heat such as a stove. • Take note of the positive and negative poles when loading the batteries. INSTALLATION PRECAUTIONS Installation in the following places may cause certain problems. You should always consult your dealer before installation. • A location where there is vapour oil. • A saline environment located close to the sea. • A site where there is sulphide gas, such as thermal spring. • A place where there are high frequency machines, such as a wireless station, a location with welding machines or a medical facility. 15 cm or more (5.9 po) 3 6 12 cm or m ore (4.7 po) Features of recommended locations: Outdoor Unit • Must be free from obstructions at air inflow and outflow. • Requires a hook bracket able to withstand its weight • Provide sufficient space around the indoor unit, as shown in the diagram. • Must be installed at least 1 m (3.3 ft) or more from the closest television or radio equipment; the centre of a room is ideal. • Must be installed away from sources of heat, steam or flammable gases. 12 cm or m ore (4.7 po) • Must provide ease of access and not exposed to strong winds. • Requires a support able to withstand its weight and to allow installation in a horizontal position on a level. • Must be installed away from neighbours to avoid inconveniences due to operating noise and discharge air. • Must be installed away from all possible sources of flammable gases. • Must allow a height difference of less than 5 m (16.4 ft) from the indoor unit and a connecting pipe length of less than 10 m (32.8 ft). • Requires sufficient space around it. • Must be installed out of access to children. To prevent flicker impressions during compressor start-up (technical process) the following installation conditions apply. 5 Air filter Battery 2 A Remote control 1 Air inlet Air outlet A 10 cm or (3.9 more po) B NOTE: Remark as per EMC Directive 89/336/EEC CAUTION • The outdoor unit should not be exposed to strong winds. • Attach the outdoor unit with 10 anchor bolts. 60 cm or more (23.6 po) Indoor Unit 4 ore or m cm 4,5 po) (1.8 ) ore 4 po or m (39. cm 100 B 60 cm or m ore (23. 6 po ) Air outlet 1. The power connection for the air conditioner has to be made at the electrical power control panel. 2. No other equipment can be connected to the electrical circuit. 3. To ensure a compliant installation, please consult your electrical contractor to find out if certain restrictions apply to products such as washing machines, air conditioners or electrical ovens. 4. For details concerning the power rating of the air conditioner, read the rating plate of the equipment. A B > 10 000 BTU 548 mm 266 mm < 10 000 BTU 458 mm 250 mm 7 • In the case of a suspended installation, follow the proper requirements. 5. To obtain answers to your questions, contact your local dealer. Caution 1. There should be at least two of the A,B or C direction free from blocking 2. The indoor unit must be installed at least 2.3 m (7.5 ft) above the floor. 1 INDOOR UNIT INSTALLATION 2. Forming the pipe and drain hose 1. Piercing the Hole and Installing the Mounting Plate 2. Connection pipe Mounting plate measurements (mm & ft) Note: The indoor unit should be installed at least 2.3 meters (7.5 ft) above the floor. 785 mm (30.9 in) 484 mm (19.07 in) Distance to the wall 120 mm or more (4.73 in) Indoor unit outline o 65mm (2.56 in) Rear-left pipe hole 43 Avoid rises and undulations. o 65 mm (2.56 in) Rear-right pipe hole 290 mm (11.43 in) 290 mm (11.43 in) 2. Attach the end of the connection pipe. 1. Installing the mounting plate 1. Install the mounting plate in a horizontal position by using the spaces provided and by anchoring it to wall framing members. 2. In the case of block, brick, concrete or similar type walls, drill 5 mm (7/64 in) holes and insert clip 2. Piercing the hole 1. Determine the pipe hole position with the mounting plate and drill a 65 mm (2.56 in) pipe hole with a slight downward angle through-wall sleeve. 2. Always use a piping hole cap when piercing a wall made of metal lath, wire lath or sheet metal. anchors for appropriate mounting screws. 3. Screw the plate to the wall. CAUTION • Connect the indoor unit first then the outdoor unit. • Bend and arrange the pipe carefully. • Insulate both auxiliary pipes. • Ensure that the drainage runoff does not inconvenience neighbours. 1. Install an electrical circuit exclusive to the air conditioner. The supply voltage must be the same as the rated voltage of the air conditioner. 2. Do not section the cable, always use full length cable. 3. The socket must be installed in a location that is within reach. 4. No electrical cables are provided with the unit. You must acquire all wiring required for installation. Power source 3. Indoor unit installation Upper hook Floating safety support Lower hook Cushioning material 1. Insert the pipe through the hole in the wall. 2. Place the upper claw at the back of the indoor unit on the upper hook of the mounting plate, then move the unit from side to side to ensure that it is securely hooked. 3. Push the lower part of the indoor unit towards the wall. 4. The manipulation of the piping connections can easily be made by raising the indoor unit using cushioning material on the remote control side between the indoor unit and the wall. Plug socket and fuse rating Cooling capacity: Cooling capacity: 10 000 BTU or less than more 10 000 BTU Single-phase voltage 10 A 60 Hz 220 V ~ 15 A Single-phase voltage 10 A 60 Hz 220 V ~ 15 A Single-phase voltage 10 A 60 Hz 220 V ~ 15 A Avoid putting the end in water. 2. When using an extension drainage hose, protect the connecting junction with a shield pipe. Wall Shield pipe Extension drain hose Drainage hose Interior of the room 5. Connecting cables 4. Electrical wiring Mounting plate 1. Run the drainage hose with a downward slope. Do not install the drainage hose as illustrated below. Connecting pipe 45 mm (1.77 in) 45 mm (1.77 in) 265 mm 10.44 in) Distance to the wall 120 mm or more (4.73 in) 1. Drain hose 1. For left piping and left gear piping, install the pipe as shown. Bend the connection pipe and lay it at a height of 43 mm (1.69 po) or less relative to the wall. Wiring Cooling capacity: less than 10 000 BTU Cooling capacity: 10 000 BTU or more 2 2 2 2 1. Remove the indoor unit chassis wiring cover (one screw) and the concave panel cover. 2. Connect the cables to the terminals in the terminal block according to their numbers. 3. Wrap the wires that are not connected to terminals with insulation tape, so that they will not come into contact with any electrical components. Concave panel cover 1 mm or more 1,5 mm or more Screw Chassis wiring cover 1 mm or more 1,5 mm or more Cooling only type 2 2 1 mm or more 1,5 mm or more CAUTION • Use cables with sufficient capacity. Certain localities legally require the use of a short circuit isolator in order to prevent electrical shock. • Do not extend the power cable. • The air conditioner has a grounded type plug which, consequently, requires a grounded outlet. • For further details, contact your local power supplier or your dealer. Connect line Terminal block of outdoor unit N 1L 2L