Download Manuel d`Installation

Transcript
INSTALLATION MANUAL FOR ROOM
Installation Parts
AIR CONDITIONER
Name of part
Remote control
Battery
Tapping screw ST4.2x25
Drainage pipe
Air filter
Wall-mounting plate
Rubber cushion
Part no.
1
2
3
(Split Wall Mounted Type)
4
5
6
• To ensure proper installation, read this manual before starting.
• Installation, repair and servicing of the air conditioner should be done only by trained and qualified
personnel and not by end users themselves.
• The air conditioner that you purchased may be slightly different than the illustrations in this manual
which are only drawings.
7
Qty
1
2
5
1
2
1
4
TIPS ON REMOTE CONTROL OPERATION
• Before installation, operate the remote
control to determine its range.
• Keep the remote control at least 1 m
from the nearest television set or stereo
system.
• Do not place the remote control in a
location that is exposed to direct sunlight
or that is close to a source of heat such
as a stove.
• Take note of the positive and negative
poles when loading the batteries.
INSTALLATION PRECAUTIONS
Installation in the following places may cause certain problems. You should always consult your dealer
before installation.
• A location where there is vapour oil.
• A saline environment located close to the sea.
• A site where there is sulphide gas, such as thermal spring.
• A place where there are high frequency machines, such as a wireless station, a location with
welding machines or a medical facility.
15 cm or more
(5.9 po)
3
6
12
cm
or m
ore
(4.7
po)
Features of recommended locations:
Outdoor Unit
• Must be free from obstructions at air inflow and
outflow.
• Requires a hook bracket able to withstand its weight
• Provide sufficient space around the indoor unit,
as shown in the diagram.
• Must be installed at least 1 m (3.3 ft) or more from the
closest television or radio equipment; the centre of a
room is ideal.
• Must be installed away from sources of heat,
steam or flammable gases.
12 cm
or m
ore
(4.7
po)
• Must provide ease of access and not exposed to
strong winds.
• Requires a support able to withstand its weight
and to allow installation in a horizontal position on
a level.
• Must be installed away from neighbours to avoid
inconveniences due to operating noise and
discharge air.
• Must be installed away from all possible sources of
flammable gases.
• Must allow a height difference of less than 5 m (16.4 ft)
from the indoor unit and a connecting pipe length of
less than 10 m (32.8 ft).
• Requires sufficient space around it.
• Must be installed out of access to children.
To prevent flicker impressions during compressor
start-up (technical process) the following installation
conditions apply.
5
Air filter
Battery
2
A
Remote control
1
Air inlet
Air outlet
A
10 cm
or
(3.9 more
po)
B
NOTE:
Remark as per EMC Directive 89/336/EEC
CAUTION
• The outdoor unit should not be exposed to strong
winds.
• Attach the outdoor unit with 10 anchor bolts.
60 cm or more
(23.6 po)
Indoor Unit
4
ore
or m
cm
4,5
po)
(1.8
)
ore
4 po
or m
(39.
cm
100
B
60
cm
or m
ore
(23.
6 po
)
Air outlet
1. The power connection for the air conditioner has to be made at the electrical power control panel.
2. No other equipment can be connected to the electrical circuit.
3. To ensure a compliant installation, please consult your electrical contractor to find out if certain
restrictions apply to products such as washing machines, air conditioners or electrical ovens.
4. For details concerning the power rating of the air conditioner, read the rating plate of the equipment.
A
B
> 10 000 BTU
548 mm
266 mm
< 10 000 BTU
458 mm
250 mm
7
• In the case of a suspended installation, follow the
proper requirements.
5. To obtain answers to your questions, contact your local dealer.
Caution
1. There should be at least two of the A,B or C
direction free from blocking
2. The indoor unit must be installed at least
2.3 m (7.5 ft) above the floor.
1 INDOOR UNIT INSTALLATION
2. Forming the pipe and drain hose
1. Piercing the Hole and Installing the Mounting Plate
2. Connection pipe
Mounting plate measurements (mm & ft)
Note: The indoor unit should be installed at least 2.3 meters (7.5 ft) above the floor.
785 mm (30.9 in)
484 mm (19.07 in)
Distance to the wall
120 mm or more
(4.73 in)
Indoor unit outline
o 65mm (2.56 in)
Rear-left pipe hole
43
Avoid rises and
undulations.
o 65 mm (2.56 in)
Rear-right pipe hole
290 mm (11.43 in)
290 mm (11.43 in)
2. Attach the end of the connection pipe.
1. Installing the mounting plate
1. Install the mounting plate in a horizontal position by
using the spaces provided and by anchoring it to
wall framing members.
2. In the case of block, brick, concrete or similar type
walls, drill 5 mm (7/64 in) holes and insert clip
2. Piercing the hole
1. Determine the pipe hole position with the mounting
plate and drill a 65 mm (2.56 in) pipe hole with a
slight downward angle through-wall sleeve.
2. Always use a piping hole cap when piercing a wall
made of metal lath, wire lath or sheet metal.
anchors for appropriate mounting screws.
3. Screw the plate to the wall.
CAUTION
• Connect the indoor unit first then the
outdoor unit.
• Bend and arrange the pipe carefully.
• Insulate both auxiliary pipes.
• Ensure that the drainage runoff does not
inconvenience neighbours.
1. Install an electrical circuit exclusive to the air conditioner. The supply
voltage must be the same as the rated voltage of the air conditioner.
2. Do not section the cable, always use full length cable.
3. The socket must be installed in a location that is within reach.
4. No electrical cables are provided with the unit. You must acquire all
wiring required for installation.
Power source
3. Indoor unit installation
Upper hook
Floating safety support
Lower hook
Cushioning material
1. Insert the pipe through the hole
in the wall.
2. Place the upper claw at the
back of the indoor unit on the
upper hook of the mounting
plate, then move the unit from
side to side to ensure that it is
securely hooked.
3. Push the lower part of the
indoor unit towards the wall.
4. The manipulation of the piping
connections can easily
be made by raising the indoor
unit using cushioning material
on the remote control side
between the indoor unit and
the wall.
Plug socket and fuse rating
Cooling capacity: Cooling capacity:
10 000 BTU or
less than
more
10 000 BTU
Single-phase voltage 10 A
60 Hz 220 V ~
15 A
Single-phase voltage 10 A
60 Hz 220 V ~
15 A
Single-phase voltage 10 A
60 Hz 220 V ~
15 A
Avoid putting the end in water.
2. When using an extension drainage hose,
protect the connecting junction with a
shield pipe.
Wall
Shield pipe
Extension drain hose
Drainage hose
Interior of the room
5. Connecting cables
4. Electrical wiring
Mounting plate
1. Run the drainage hose with a downward slope.
Do not install the drainage hose as illustrated
below.
Connecting pipe
45 mm (1.77 in)
45 mm (1.77 in)
265 mm 10.44 in)
Distance to the wall
120 mm or more
(4.73 in)
1. Drain hose
1. For left piping and left gear piping, install
the pipe as shown. Bend the connection pipe
and lay it at a height of 43 mm (1.69 po) or
less relative to the wall.
Wiring
Cooling capacity:
less than
10 000 BTU
Cooling capacity:
10 000 BTU or
more
2
2
2
2
1. Remove the indoor unit chassis wiring cover (one screw) and the
concave panel cover.
2. Connect the cables to the terminals in the terminal block according
to their numbers.
3. Wrap the wires that are not connected to terminals with insulation
tape, so that they will not come into contact with any electrical
components.
Concave panel cover
1 mm or more 1,5 mm or more
Screw
Chassis wiring cover
1 mm or more 1,5 mm or more
Cooling only type
2
2
1 mm or more 1,5 mm or more
CAUTION
• Use cables with sufficient capacity. Certain localities legally require the use
of a short circuit isolator in order to prevent electrical shock.
• Do not extend the power cable.
• The air conditioner has a grounded type plug which, consequently, requires
a grounded outlet.
• For further details, contact your local power supplier or your dealer.
Connect line
Terminal block of outdoor unit
N
1L 2L