Download E - Active srl

Transcript
ENGLISH
GB
13
ACCELERATOR FAULT
CHECK ACCELERATOR DEVICE
15
BATTERY VOLTAGE TOO
LOW
RECHARGE BATTERY
18
CHECK ELECTRONIC
FAULT
VERIFY MOTOR ISOLATION;
IF OK, REPLACE CONTROL
19
CHECK ELECTRONIC
FAULT
VERIFY MOTOR ISOLATION;
IF OK, REPLACE CONTROL
20
CHECK ELECTRONIC
FAULT
VERIFY MOTOR ISOLATION;
IF OK, REPLACE CONTROL
21
FAULT LINE
CONTACTOR REEL
CHECK REEL CONNECTION
22
BATTERY VOLTAGE TOO
HIGH DURING
LOWERING
23
CHECK ELECTRONIC
FAULT
VERIFY MOTOR ISOLATION AND THE
KEY (11); IF OK, REPLACE CONTROL
24
CHECK ELECTRONIC
FAULT
CHECK ELECTRICAL SYSTEM OR
THE KEY (11)
25
FAULT LINE
CONTACTOR
CHECK THE KEY (11) CONTACTS
26
CHECK ELECTRONIC
FAULT
REPLACE ELECTRONIC CONTROL
27
CHECK ELECTRONIC
FAULT
SWITCH THE MANICHE ON AND OFF.
IF PROBLEM PERSISTS, CHANGE
CONTROL
28
WIRE CONNECTION
INCORRECT
CHECK CONNECTOR A AND
PINS 8 - 9 - 16
PUT ON THE LOWEST GEAR
11. STORAGE
Park in a dry place, away from salt. Keep batteries charged
(check monthly). If the machine remains stopped for over
a month, disconnect the connection cables to the batteries,
pulling the terminals from the poles, avoiding metal sheets
with polarity +.
In seaside areas, it is advisable to wash the machine with
fresh water, avoiding wetting the electric motor and the
box containing the electrical and electronic equipment,
dry and grease it at all points. Remove the electrical system
cover (14) (see fig.2) and spray with a protective spray for
electrical systems