III. 7. TROUBLESHOOTING
III. 7.1 Trouble and causes of air conditioner
If one of the following malfunctions occur, stop operation, shut off the power, and contact with the dealer.
Indicator lamps flash rapidly (5Hz), after your disconnecting and connecting the unit again, the
situation is the same.
Fuse or circuit breaker work frequently.
TROUBLES Foreign matter or matter has fallen into the unit.
Remote controller is disabled or the switch is out of order.
Any other unusual condition is observed.
Table 6-1 For the model 3500 W
NO.
MALFUNCTION & PROTECTION DEFINE
LED1
LED2
LED3
LED4
OPERATION TIMER DEF.FAN ALARM
DISPLAY
DIGITAL TUBE
1
Room temperature sensor checking channel is abnormal
E0
2
Pipe temperature sensor checking channel is abnormal
E1
3
In-Outdoor unit COMM. checking channel is abnormal
E2
4
Water level alarm malfunction
E3
5
EPPROM malfunction
E4
6
Module malfunction
E5
7
Outdoor TEMP. sensor checking channel is abnormal
E6
8
Outdoor voltage protection
P0
9
Compressor temperature protection
P1
10
Outdoor current system protection
P2
11
Be closed by the remote control function
CP
12
Avoid cold wind & Defrost
Extinguish
Flashing at 5Hz
Flashing at 1Hz
Table 7-2: For the models 5300 W – 17600 W
NO
LED1
OPERATION
MALFUNCTION & PROTECTION DEFINE
LED2 LED3
LED4
DISPLAY
TIMER DEF.FAN ALARM DIGITAL TUBE
1
Collision mode malfunction
E0
2
In-Outdoor unit COMM. Checking channel is abnormal
E1
3
Room TEMP. sensor checking channel is abnormal
E2
4
Pipe TEMP. Sensor checking channel is abnormal (T2)
E3
5
Pipe TEMP. Sensor checking channel is abnormal (T2B)
E4
6
EPPROM malfunction
E7
7
Water-level alarm malfunction
EE
8
Outdoor malfunction
Ed
9
Be closed by the remote control function
CP
10
Avoid cold fan & Defrost
Extinguish
Flashing at 5Hz
Flashing at 1Hz