Download SINUS PENTA

Transcript
SINUS PENTA
BASIC
USER MANUAL
2.3.4.7.
CONNECTION BARS
44/U
47/+
47/D
45/V
49/–
41/R
FOR
S41–S42–S51–S52
46/W
42/S
43/T
CAUTION
Connection bars 47/D and 47/+ are short-circuited as a factory setting. The DC
choke, if any, shall be linked between bars 47/D and 47/+ after removing the shortcircuit.
CAUTION
Please contact Elettronica Santerno if DC supply is to be applied to SINUS PENTAs
S41, S42, S51, S52.
NOTE
2.3.4.8.
Use terminals 47/+ and 49/– if the external braking unit is to be installed.
S60 C O N N E C T I O N
BARS
CAUTION
The figure above shows the position and the wiring instructions for the built-in power
supply transformer. The transformer must be wired based on the rated supply voltage
applied.
CAUTION
Connection bars 47/D and 47/+ are short-circuited as a factory setting. The DC
choke, if any, shall be linked between bars 47/D and 47/+ after removing the shortcircuit.
CAUTION
Please contact Elettronica Santerno if DC supply is to be applied to SINUS PENTA S60.
21/82