Download Triton 9700 Error Codes
Transcript
MODEL 97XX INSTALLATION AND SERVICE MANUAL STATUS CODE P ERROR CODE 332(50h) DEFINITION/CAUSE: Cassettes May Have Been Changed. This status is generated when a movement command is sent before a READ CASSETTE ID command after the cassettes, including the Reject Vault are removed. This is status will set a LOCKOUT condition. RECOMMENDED ACTIONS: Verify that each cassette is placed in its designated feed channel. Complete the TEST RECEIPT PRINTER function to determine which if any of the cassettes are not responding. If a cassette is not responding is may be necessary to program the cassette by completing the INJECT NEW CASSETTE ID Function. Additionally, this problem may be caused by a defective cassette. STATUS CODE Q ERROR CODE 333(51h) DEFINITION/CAUSE: Reject Vault Full. This status is produced when the internal counter for the bundle reject exceeds 250 notes or the reject counter for the single reject exceeds 50. This status will cause a LOCKOUT condition. RECOMMENDED ACTIONS: To clear this status the Reject Vault must be removed, emptied, and inserted with the power on to provide the proper sequence to reset the internal reject counters. 7-64 PRELIMINARY