Download Triton 9700 Error Codes

Transcript
MODEL 97XX INSTALLATION AND SERVICE MANUAL
STATUS CODE ‘P’ ERROR CODE ‘332’(50h)
DEFINITION/CAUSE:
Cassettes May Have Been Changed. This status is
generated when a movement command is sent before
a READ CASSETTE ID command after the cassettes,
including the Reject Vault are removed. This is status will set a LOCKOUT condition.
RECOMMENDED ACTIONS:
Verify that each cassette is placed in its designated
feed channel. Complete the TEST RECEIPT
PRINTER function to determine which if any of the
cassettes are not responding. If a cassette is not responding is may be necessary to program the cassette
by completing the INJECT NEW CASSETTE ID
Function. Additionally, this problem may be caused
by a defective cassette.
STATUS CODE ‘Q’ ERROR CODE ‘333’(51h)
DEFINITION/CAUSE:
Reject Vault Full. This status is produced when the
internal counter for the bundle reject exceeds 250 notes
or the reject counter for the single reject exceeds 50.
This status will cause a LOCKOUT condition.
RECOMMENDED ACTIONS:
To clear this status the Reject Vault must be removed,
emptied, and inserted with the power on to provide
the proper sequence to reset the internal reject
counters.
7-64