Q600 Series - Remote Characteristics may vary depending on operating conditions. CYCLE TIMES Freeze Time + Harvest Time = Total Cycle Time Freeze Time Air Temp. Entering Condenser °F/°C 50/10.0 70/21.1 90/32.2 -20/-28.9 to 70/21.1 7.9-9.4 8.9-10.5 9.5-11.2 80/26.7 8.0-9.4 9.0-10.6 9.6-11.3 90/32.2 8.1-9.5 9.1-10.7 9.7-11.4 Harvest Time Water Temperature °F/°C 1-2.5 100/37.8 8.4-9.9 9.5-11.2 10.1-11.9 110/43.3 8.9-10.5 10.1-11.9 10.9-12.8 Times in minutes 24 HOUR ICE PRODUCTION Air Temp. Entering Condenser °F/°C 50/10.0 Water Temperature °F/°C 70/21.1 90/32.2 -20/-28.9 to 70/21.1 630 570 540 80/26.7 625 565 535 90/32.2 620 560 530 100/37.8 600 540 510 110/43.3 570 510 480 Based on average ice slab weight of 4.12 - 4.75 lb. Regular cube derate is 7% Ratings with JC0895 condenser, dice or half-dice cubes OPERATING PRESSURES Air Temp. Entering Condenser °F/°C Freeze Cycle Harvest Cycle Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG -20/-28.9 to 50/10.0 220-250 42-26 152-170 75-100 70/21.1 225-260 44-26 155-172 82-100 80/26.7 245-265 46-26 156-174 82-100 90/32.2 250-265 48-26 157-174 84-100 100/37.8 265-295 52-26 158-176 84-100 110/43.3 300-335 52-28 158-176 84-105 Suction pressure drops gradually throughout the freeze cycle –133–