Download fuel injection pump
Transcript
Test Bench Data Also, test bench calibration fluid must be used. A WARNING Keep hands away from nozzle tip when popping a nozzle. The finely atomized fuel is ejected with sufficient force to penetrate the skin and cause blood poisoning. Also, wear safety glasses with side shields or goggles when popping a nozzle. PRESSURE TEST Install nozzle holder assembly on nozzle tester as shown in Fig. 8-1. Install spray collector. T-50066 FIG. 8-1 FUEL INJECTION NOZZLE TESTER 1. 2. 3. 4. 5. 6. 7. 8. Pressure adjusting screws Adjusting screw locknut Filler cap Pressure gauge Valve handle Tester handle (pump) Spray collector Nozzle-holder assembly NOTE: Part numbers, ADN...(nozzles) and AKB... (holders) are American Bosch part numbers ; EFE P. . and EF.. . number s are Robert Bosch part numbers. CALIBRATING NOZZLE TESTING NOTE: Nozzle assemblies should be tested at least monthly, or after each 20 pumps have been tested. Calibrating nozzles must be handled as you would handle a delicate gauge. In this respect, the nozzles should not be disassembled for repair unless your shop is completely equipped; "equipped", will include a master calibrating fuel injection pump. Unless "completely equipped", only two tests should be made; pressure test and nozzle seating test. To properly test a nozzle and holder assembly, a nozzle tester (with a recently calibrated gauge) similar to the one shown in Fig. 8-1 is required. Open nozzle tester valve and operate the handle several strokes to force the air out of the nozzle assembly. Operate tester handle a few quick strokes then observe the opening pressure (should be 2500 psi -- 175.8 kg/cm ) Adjust the fuel injection nozzle to obtain specified opening pressure (if necessary) as follows: Remove the cap nut from the upper end of the fuel injection nozzle holder and loosen the adjusting screw locknut. While operating the tester pump handle, turn the pressure adjusting screw IN to increase or OUT to decrease the opening pressure until the specified pressure is obtained. At this time, hold the adjusting screw from turning and tighten the adjusting screw locknut to the specified torque as follows: NOZZLE NO. TORQUE ADN8S2C 44--58 (6--8 m-kg) ADNI2SD12 44--58ft. lbs. (6-8 m-kg) EFEP 182 44--58ft. lbs. (6-8 m-kg) On all tests, check for leakage between nozzle and holder bodies--a slight seepage is permissable. NOZZLE VALVE SEATING TEST Slowly operate tester until nozzle opens. Wipe the tip of nozzle until thoroughly dry. Study SAFETY RULES in the front of this manual thoroughly for the protection of machine and safety of personnel. SERVICE MANUAL FORM 73112988 8-3 (Revised January 1979)