Download fuel injection pump

Transcript
Test Bench Data
Also, test bench calibration fluid must be
used.
A
WARNING
Keep hands away from nozzle tip when
popping a nozzle. The finely atomized fuel
is ejected with sufficient force to penetrate
the skin and cause blood poisoning. Also,
wear safety glasses with side shields or
goggles when popping a nozzle.
PRESSURE TEST
Install nozzle holder assembly on nozzle
tester as shown in Fig. 8-1. Install spray
collector.
T-50066
FIG. 8-1 FUEL INJECTION NOZZLE
TESTER
1.
2.
3.
4.
5.
6.
7.
8.
Pressure adjusting screws
Adjusting screw locknut
Filler cap
Pressure gauge
Valve handle
Tester handle (pump)
Spray collector
Nozzle-holder assembly
NOTE: Part numbers, ADN...(nozzles) and
AKB... (holders) are American Bosch part
numbers ; EFE P. . and EF.. . number s are
Robert Bosch part numbers.
CALIBRATING NOZZLE TESTING
NOTE: Nozzle assemblies should be tested
at least monthly, or after each 20 pumps
have been tested.
Calibrating nozzles must be handled as you
would handle a delicate gauge. In this respect,
the nozzles should not be disassembled for
repair unless your shop is completely
equipped; "equipped", will include a master
calibrating fuel injection pump.
Unless "completely equipped", only two
tests should be made; pressure test and
nozzle seating test. To properly test a
nozzle and holder assembly, a nozzle tester
(with a recently calibrated gauge) similar
to the one shown in Fig. 8-1 is required.
Open nozzle tester valve and operate the
handle several strokes to force the air out
of the nozzle assembly.
Operate tester handle a few quick strokes
then observe the opening pressure (should
be 2500 psi -- 175.8 kg/cm )
Adjust the fuel injection nozzle to obtain
specified opening pressure (if necessary)
as follows:
Remove the cap nut from the upper end of
the fuel injection nozzle holder and loosen
the adjusting screw locknut.
While operating the tester pump handle, turn
the pressure adjusting screw IN to increase
or OUT to decrease the opening pressure
until the specified pressure is obtained. At
this time, hold the adjusting screw from
turning and tighten the adjusting screw locknut to the specified torque as follows:
NOZZLE NO. TORQUE
ADN8S2C 44--58 (6--8 m-kg)
ADNI2SD12
44--58ft. lbs. (6-8 m-kg)
EFEP 182
44--58ft. lbs. (6-8 m-kg)
On all tests, check for leakage between
nozzle and holder bodies--a slight seepage is
permissable.
NOZZLE VALVE SEATING TEST
Slowly operate tester until nozzle opens.
Wipe the tip of nozzle until thoroughly dry.
Study SAFETY RULES in the front of this manual thoroughly for the protection of machine and safety of personnel.
SERVICE MANUAL FORM 73112988
8-3
(Revised January 1979)