Download spec A-C
Transcript
PLASTIC COVER ELEMENT COVER FIGURE 6-19. CHOKE ASSEMBLY . 4. Refer to Table 6-3 to determine the number of degrees element cover must be rotated (clockwise) from reference position. Marks on choke housing are spaced at 5' intervals. 5. Rotate elementcover asspecifiedand then tighten cover mounting screws. 6. Move choke lever back and forth to check for smooth operation. Lever should return automatically to the free position when released from the open position without sticking or binding. 7. Install plastic choke cover and tighten center mounting nut. Choke Replacement: If the choke fails to open, remove the protective plastic cover and check to see if the heatingelement is working. The heatingelement cover should become hot after a few minutes of operation. If the element cover does not get hot, start the set and then use an AC voltmeter to check forvoltage (approximately 20 VAC) at the element cover terminals. If voltage is not present, check for opens or shorts in the control wiring. If the voltage is present at the heating element cover terminals,stop the set and removethe heatingelement cover. Inspect the heating element and replace if burned out or broken. Also inspect the bi-metal spiral strip and replace if damaged, deteriorated, ordragging in the housing. When installing a new bi-metal strip, maintainthe original direction of spiral (see Figure 6-20). The outer tab 6-18 must point in a clockwise direction. Make sure the coil sets squarely in the housing and the inner end of the coil engages the slot in the choke shaft. When installing the element cover, make sure the slotted tang on the cover engages the bi-metal strip. OZTER TAB FS-1606 FIGURE 6-20. BI-METAL SPIRAL STRIP Choke Pul/off Diaphragm Adjustments: The choke pulloff diaphragm partially opens thechoke plate following engine startup. This helps prevent flooding and provides for smoother engine operation as the set is warming up. Use the following procedure to adjust. 1. Remove the complete air filter assembly as specified in Air Filter Assembly in thissection to provide access to the choke plate. 2. Disconnect diaphragm hose from intake manifold and apply4 to 18 inches (102 to457 mm) Hg Redistribution or publication of this document, vacuum to the diaphragm. by any means, is strictly prohibited.