PLASTIC COVER
ELEMENT COVER
FIGURE 6-19. CHOKE ASSEMBLY
.
4. Refer to Table 6-3 to determine the number of
degrees element cover must be rotated (clockwise)
from reference position. Marks on choke housing
are spaced at 5' intervals.
5. Rotate elementcover asspecifiedand then tighten
cover mounting screws.
6. Move choke lever back and forth to check for
smooth operation. Lever should return automatically to the free position when released from the
open position without sticking or binding.
7. Install plastic choke cover and tighten center
mounting nut.
Choke Replacement: If the choke fails to open, remove
the protective plastic cover and check to see if the
heatingelement is working. The heatingelement cover
should become hot after a few minutes of operation. If
the element cover does not get hot, start the set and
then use an AC voltmeter to check forvoltage (approximately 20 VAC) at the element cover terminals. If
voltage is not present, check for opens or shorts in the
control wiring.
If the voltage is present at the heating element cover
terminals,stop the set and removethe heatingelement
cover. Inspect the heating element and replace if
burned out or broken. Also inspect the bi-metal spiral
strip and replace if damaged, deteriorated, ordragging
in the housing.
When installing a new bi-metal strip, maintainthe original direction of spiral (see Figure 6-20). The outer tab
6-18
must point in a clockwise direction. Make sure the coil
sets squarely in the housing and the inner end of the
coil engages the slot in the choke shaft. When installing the element cover, make sure the slotted tang on
the cover engages the bi-metal strip.
OZTER
TAB
FS-1606
FIGURE 6-20. BI-METAL SPIRAL STRIP
Choke Pul/off Diaphragm Adjustments: The choke
pulloff diaphragm partially opens thechoke plate following engine startup. This helps prevent flooding
and provides for smoother engine operation as the
set is warming up. Use the following procedure to
adjust.
1. Remove the complete air filter assembly as specified in Air Filter Assembly in thissection to provide
access to the choke plate.
2. Disconnect diaphragm hose from intake manifold and apply4 to 18 inches (102 to457 mm) Hg
Redistribution or publication of this document,
vacuum to the diaphragm.