Download Modine Ductless Split Installer`s Guide - H
Transcript
UNIT LOCATION Electrical Data – Ceiling Cassettes Exploded Unit Drawing & Parts List: SCW 2/8 & SCW 2/12 Exploded Unit Drawing & Parts List: SSD/SSH/SCW 18 - 42 Maintenance – Indoor Unit Maintenance Schedule Filter Removal and Cleaning Recommended Spares Disassembly Procedure Fan Removal Condensate Tray Removal Condensate Pump Removal Troubleshooting – Indoor Unit Replacement Parts Warranty 1. 19 20 2. 21 22 22 22 22 22 22 22 22 23-26 26 28 3. 4. 5. 6. 7. Table 3.1 SI (Metric) Conversion Factors To Convert Multiply By To Obtain To Convert “W.C. ºF BTU BTU/ft3 BTU/hr CFH (ft3/hr) CFH (ft3/hr) CFM (ft3/min) CFM (ft3/min) 0.249 (ºF-32) x 5/9 1.06 37.3 0.000293 0.000472 0.00000787 0.0283 0.000472 kPa ºC kJ kJ/m³ kW m³/min m³/s m³/min m³/s feet Gal/hr Gal/hr gallons Horsepower inches pound psig psig Multiply By 0.305 0.00379 3.79 3.79 746 25.4 0.454 6.89 27.7 To Obtain 8. m m³/hr l/hr l W mm kg kPa “W.C. The appliance must be installed on a structure that is suitable to support the total weight of the appliance, piping, refrigerant and condensate. Piping, electrical panel and condensate pump access panel should be readily accessible for maintenance purposes. A clearance of 2 feet is recommended around the electrical panel and condensate pump access panel. The unit should not be positioned less than 5 ft. from a wall or similar obstruction, or in a position where the discharge air could blow directly on to the thermostat. The unit should not be positioned directly above any obstructions. The unit must be installed square and level. The condensate drain should have sufficient downward slope (1” in 100”) in any horizontal run between unit and drain. Maximum condensate pump lift is 30”. There should be sufficient room above the false ceiling for installing the unit. Minimum distance as shown in Figure 3.1 and Table 3.2. In case of high humidity, clogged or damaged condensate piping, incorrect installation or faulty condensate pump, water may drip from the unit. Do not install the appliance where dripping water can cause damage. Figure 3.1 Minimum Distance to Ceiling UNIT LOCATION DANGER 30” max Appliances must not be installed where they may be exposed to potentially explosive or flammable atmosphere. A Table 3.2 Minimum Distance to Ceiling Unpacking Remove the banding straps and lift the cardboard lid. Remove the fascia, packed in bubble wrap, and polystyrene packing pieces to expose the unit. Models When removing the unit chassis from the box, the four corner brackets should be utilized for lifting. In order to protect the fascia from dirt and damage, it should be returned to the box until it is ready to be installed. Blank Off Pieces When branch ducting is to be used, polystyrene pieces for blanking off fascia openings are included with the fascia packing. Up to two opposing sides may be blanked off. See Installation – Duct Collars. A SCW 2/8 & 2/12 12¾” SCW 18 & 20 11½” SCW 33, 36 & SSD/SSH 18 - 42 13½” Ceiling Opening Sizes An opening in the false ceiling will then have to be cut to the size shown in Table 3.3. Table 3.3 Ceiling Opening Sizes Positioning Before any installation work commences, the condensing unit location (where applicable), pipe work sizes and routes should be designed in accordance with good refrigeration practice. Models The unit installation position should be selected with the following points in mind: LxW SCW 2/8 & 2/12 23” x 23” SSD/SSH/SCW 18, 20 & 24 34” x 34” SSD/SSH/SCW 30, 33, 36 & 42 46” x 34” 3 8-504.5