Download MAINTENANCE MANUAL
Transcript
to select weight units. --To employ all (metric and pound/oz) weight units, press MODE until ‘g’(kg), ‘lb’ indicators appear. --To disable ‘lb’ weight unit, press MODE until ‘g’(kg) indicator appears only. SELECT SCALE CAPACITY e. Press MODE to select the capacity, Press TARE to save setting. f. Re-calibration will be required after scale capacity changed. F4 Auto Power Off Setting Two modes are available: (Default=4_OFF) Press MODE until desired setting appear, press TARE to save setting. 0_OFF = Auto Power Off function is disabled. 4_OFF = Scale will automatically turns it off after 4 minutes unused. F9 Auto Tare Two modes TroFF = Tr_on = Setting are available: (Default=TroFF) Auto tare function is disabled. Scale will automatically tare off the initial weight that places on the platter. ** F19~F21 Reserved 8