Download MAINTENANCE MANUAL

Transcript
to select weight units.
--To employ all (metric and pound/oz) weight units, press
MODE until ‘g’(kg), ‘lb’ indicators appear.
--To disable ‘lb’ weight unit, press MODE until ‘g’(kg)
indicator appears only.
SELECT SCALE CAPACITY
e. Press MODE to select the capacity, Press TARE to save
setting.
f. Re-calibration will be required after scale capacity
changed.
F4 Auto Power Off Setting
Two modes are available: (Default=4_OFF)
Press MODE until desired setting appear, press TARE to save
setting.
0_OFF =
Auto Power Off function is disabled.
4_OFF =
Scale will automatically turns it off after 4 minutes
unused.
F9 Auto Tare
Two modes
TroFF =
Tr_on =
Setting
are available: (Default=TroFF)
Auto tare function is disabled.
Scale will automatically tare off the initial weight that
places on the platter.
**
F19~F21 Reserved
8