Download 0 - i-Logic Software

Transcript
10. STANDARD lNPUT/OUTPUT DIAGNOSIS
10.1 STANDARD lNPUT/OUTPUT
DIAGNOSIS NUMBER LIST
A list of standard 1/0 diagnosis numbers and 1/0 signal names is shown
below.
D7 D6 D5 D4 D3 D2 D1 DO
Display methed :
0
0
0
0
1
1
L Contact is open.
1
1
I Contact is closed.
Diagnosis No.
Details
#3000 to #3009
‘#3010 to #3019
#3020 to #3029
#3030 to #3039
#3040 to #3049
#3070 to #3079
Input signal PLC + NC
Input signal from strong electric sequence. ( PLC)
Input signal from strong electric sequence.
Input signal from strong electric sequence.
Input signal from strong electric sequence.
Input signal from strong electric sequence.
(X-axis to 5th axis servo axes control 1/2)
Input signal from strong electric sequence.
( X-axis to 5th axis servo axes control 2/2)
Input signal from strong electric sequence.
(Spindle control)
Output signal to strong electric sequence. (PLC)
Output signal to strong electric sequence.
Output signal to strong electric sequence.
Output signal to strong electric sequence.
Output signal to strong electric sequence.
Output signal to strong electric sequence.
(X-axis to 5th axis servo axes control 1/3)
Output signal to strong electric sequence.
(X-axis to 5th axis servo axes control 2/3)
Output signal to strong electric sequence.
(X-axis to 5th axis servo axes control 3/3)
Output signal to strong electric sequence.
Spindle control signal
Exclusive PLC use. Constant
#3080 to #3089
#3110 to #3119
#3500 to #3505
#3514 to #3519
#3520 to #3529
#3530 to #3539
#3540 to #3543
#3610 to #3619
#3630 to #3639
#3640 to #3643
#3650 to #3659
#3990 to #3999
–
319
–