Download ATOMLAB 400 DOSE CALIBRATOR

Transcript
ATomlAb Dose Calibrator operation manual
Appendix I
The accuracy for dial value calculation depends upon not only the accuracy of
the sensitivity curve and the photon emission intensity data, but also upon the
sample configuration, due to low energy photon absorption (see Radioisotope
container below). The photon sensitivity curve displayed is for sources with
configurations similar to the NIST ampoule configuration noted above.
All Atomlab dose calibrators are calibrated with NIST traceable Co-60, Ba-133,
Co-57, and Cs-137 sources. Each dose calibrator is certified to measure the
correct activity of the calibration sources to within the specified accuracy.
The following factors can affect measurement accuracy and should be taken into
consideration when using the Atomlab dose calibrator:
Lead Shield: A lead shield is necessary to protect personnel from exposure to the
radiation produced by radioactive isotopes. This lead shield is integrally installed
as part of the Atomlab dose calibrator. However, photon backscatter occurs from
the lead shield, resulting in increased chamber sensitivity in the 88-200 keV
photon energy range. This increase in sensitivity is already included in the
sensitivity curve above, and it can be easily seen in the peak at 88 keV. However,
if for any reason the dose calibrator is operated without the integral shield
installed, the sensitivity curve will be incorrect in this energy range, resulting in
incorrect measurements for isotopes which emit photons in this range. It is
recommended that the dose calibrator always be operated with the lead shield in
place.
Radioisotope container: The style and type of container a radioisotope is in can
effect the measurement. Users should have a standard procedure, container,
and solution volume for measuring radioisotopes. Plastic syringes are often used
as a standard container as they are usually the means of delivery to the patient
in a clinical environment. The dial values generated using the photon sensitivity
curve above should be appropriate for most plastic and thin glass syringes.
Glass vials may require a correction factor for some isotopes.
The wall thickness of the container is especially important when measuring
isotopes which emit low energy photon and/or high energy beta radiation. I-125,
I-123, and Xe-133 are especially susceptible to errors caused by low energy
photon absorption. In cases where a container has a wall thickness or material
significantly different from the NIST standards used above, it is recommended that
a correction factor or corrected dial value be used to correct for the difference in
absorption between the NIST configuration and the configuration used in clinical
practice. Whichever container and configuration is used in clinical practice, it is
strongly recommended that such configuration be standardized and used every
single time.
biodex medical Systems
I-3