ATomlAb Dose Calibrator operation manual Appendix I The accuracy for dial value calculation depends upon not only the accuracy of the sensitivity curve and the photon emission intensity data, but also upon the sample configuration, due to low energy photon absorption (see Radioisotope container below). The photon sensitivity curve displayed is for sources with configurations similar to the NIST ampoule configuration noted above. All Atomlab dose calibrators are calibrated with NIST traceable Co-60, Ba-133, Co-57, and Cs-137 sources. Each dose calibrator is certified to measure the correct activity of the calibration sources to within the specified accuracy. The following factors can affect measurement accuracy and should be taken into consideration when using the Atomlab dose calibrator: Lead Shield: A lead shield is necessary to protect personnel from exposure to the radiation produced by radioactive isotopes. This lead shield is integrally installed as part of the Atomlab dose calibrator. However, photon backscatter occurs from the lead shield, resulting in increased chamber sensitivity in the 88-200 keV photon energy range. This increase in sensitivity is already included in the sensitivity curve above, and it can be easily seen in the peak at 88 keV. However, if for any reason the dose calibrator is operated without the integral shield installed, the sensitivity curve will be incorrect in this energy range, resulting in incorrect measurements for isotopes which emit photons in this range. It is recommended that the dose calibrator always be operated with the lead shield in place. Radioisotope container: The style and type of container a radioisotope is in can effect the measurement. Users should have a standard procedure, container, and solution volume for measuring radioisotopes. Plastic syringes are often used as a standard container as they are usually the means of delivery to the patient in a clinical environment. The dial values generated using the photon sensitivity curve above should be appropriate for most plastic and thin glass syringes. Glass vials may require a correction factor for some isotopes. The wall thickness of the container is especially important when measuring isotopes which emit low energy photon and/or high energy beta radiation. I-125, I-123, and Xe-133 are especially susceptible to errors caused by low energy photon absorption. In cases where a container has a wall thickness or material significantly different from the NIST standards used above, it is recommended that a correction factor or corrected dial value be used to correct for the difference in absorption between the NIST configuration and the configuration used in clinical practice. Whichever container and configuration is used in clinical practice, it is strongly recommended that such configuration be standardized and used every single time. biodex medical Systems I-3