Download GUVA TECH INFO
Transcript
GY-12 BR-13 10 YL-20 C C NO R OR-22 C HI GAS VALVE BR-13 PM RD WH BK Y1 W2 W1 RD-15 WH-7 RD-2 NO BU-12 BU-36 C BK-3 OR-10 BU-38 HOT SURFACE IGNITER 2 PIN CONNECTOR AUTO RESET PRIMARY LIMIT CONTROL PK-30 RD-2 C1 C2 R3 WH-33 VT-28 EM/W2 O R2 W1 GN WH-42 BK-41 VT-28 PK-30 GY-8 6 PIN CONNECTOR 115 VAC L GND N JUNCTION BOX WITH BLOWER COMPARTMENT DOOR SWITCH GND INDOOR AIR CIRCULATION BLOWER ELECTRONIC AIR CLEANER C C CIRC-N EAC-N IND-N HUM-N IGN-N XFMR-N MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 45 KBTU) NO GAS VALVE C HI PM FRONT COVER PRESSURE SWITCH LOW FIRE PRESSURE SWITCH MANUAL RESET AUXILIARY LIMIT CONTROLS AUTO RESET PRIMARY LIMIT CONTROL 40 VA TRANSFORMER 24 VAC 115 VAC GND LINE-N DISCONNECT TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. DOOR SWITCH INDUCTOR COIL (NOT ALL MODELS) LINE-H EAC H IND LO ID BLWR HUMIDIFIER HOT SURFACE IGNITER C DISCONNECT RD-37 WH-32 VT-28 40 VA TRANSFORMER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE IGNITER SWITCH (TEMP.) FIELD SPLICE FIELD GND EQUIPMENT GND L GND N WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. GND NO HIGH FIRE PRESSURE SWITCH NO FLAME SENSOR C1 R3 TR(9) GND(4) MVCOM(8) MVH(1) PS2(2) MVL(7) PS1(12) HLI(6) HLO(11) TH(5) CIRC INPUT IND HI IGN H HUM H FP (3) COOL Y/ Y2 R2 XFMR-H W1 INTERFACE BOARD EM/ W2 HEAT LO TO MICRO TO MICRO PLUG CONNECTION TERMINAL INTERNAL TO INTEGRATED CONTROL JUNCTION HI VOLTAGE FIELD HI VOLTAGE (115V) LOW VOLTAGE FIELD LOW VOLTAGE (24V) JUNCTION BOX WITH BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR IS OPEN) BK -1 INTEGRATED CONTROL MODULE C W2 G Y W1 R HEAT HI OR-10 GY-8 WH-5 BK-4 24V THERMOSTAT CONNECTIONS BU-38 WH-33 G Y/Y2 STEADY ON = REPLACE CONTROL VT-28 BK-44 WH-46 0 1 FLASH = INTEGRATED CONTROL MODULE RD 3 PIN CONNECTOR INDUCED DRAFT BLOWER Y2 DIAGNOSTIC LED PK-30 HUM EAC CIR XFMR LINE IGN-N IND-N IND-LO IND-HI EAC HUM IGN XMFR CIRC INPUT LINE HEAT-HI HEAT-LO INDOOR AIR CIRCULATION BLOWER COOL BU -27 GY-47 VT-25 HIGH FIRE PRESSURE SWITCH FRONT COVER PRESSURE SWITCH G BLOWER COMPARTMENT BURNER COMPARTMENT GND PK -17 MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 45 KBTU) RD-18 WH YL WH BK THERMOSTAT CONNECTIONS C LOW FIRE PRESSURE SWITCH BK 5 PIN CONNECTOR WH-45 PK-47 BK-37 1 2 FLASHES = PRESSURE SWITCH STUCK CLOSED OR-10 BK-31 24 VAC PK-30 NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. TO 115 VAC/ 1Ø / 60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. GUVA___AX__ INTEGRATED CONTROL MODULE 11 RD GND 2 3 FLASHES = PRESSURE SWITCH STUCK OPEN INDUCTOR COIL GUVA070,090,115 MODELS ONLY 3 4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN RD-37 4 CONTINUOUS FLASHES = UNANTICIPATED FLAME PRESENT WH WHITE BU BLUE GY GRAY RD RED PK PINK BR BROWN SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) C COLOR CODES: YL YELLOW OR ORANGE VT VIOLET GN GREEN BK BLACK 20276101 REV.00 MANUAL RESET AUXILIARY LIMITS 7 OR-15 8 GN 4 VT-25 5 12 YL-20 1 9 ON BU-36 2 6 1 2 FLAME SENSOR 3 PS1 HLO GND INTEGRATED CONTROL MODULE TR GY-8 YL MVMVL COM INTERFACE BOARD NEUTRAL 120VAC HOT 120VAC GND TH HLI NO WIRING DIAGRAMS 16 Rev. 1 TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY, OR DEATH, DISCONNECT THE POWER BEFORE SERVICING. ! WARNING CIRCULATOR BLOWER PS2 MVH FP