Download section 1 - Victor Technologies

Transcript
Chart #1: Main Power
AC Indicator OFF
on Front Panel
System
Operates
Properly?
No
AC POWER
Switch ON?
Power Cable
Plugged In?
Yes
Connect AC Power
Input Cable to
AC Source
No
Yes
Yes
No
Faulty AC Indicator
Replace Main Power
Assembly
Check Main
Power Disconnect
Place AC POWER
Switch to ON
Place Main Power
Disconnect to ON
Main Power
Disconnect ON?
No
Yes
Check Main Disconnect
Power Line Fuses
Unplug Power Supply
From Main Power Source
Yes
Main Power
Line Fuses
Replaced
Once?
No
Yes
Main Power
Line Fuses
Okay?
Replace Main
Power Line Fuses
No
Main Power
Line Fuses
Okay?
Yes
Unplug Power Supply
From Main Power Source
Proceed to Chart #2
No
Proceed to Chart #2
Check Main Disconnect
Power Line Fuses For
Proper Amperage
Faulty Main
Power Source
Manual 0-2671
17
CUSTOMER/OPERATOR SERVICE