Download ineo+ 6500
Transcript
7. HT-503 (OPTIONAL) LU-202/HT-503 7.2 Theory of Operation Ver1.0 Sep.2006 Operation 7.2.1 Dehumidifier fan heater control A. Outline • The fan heater (HTR3) and the dehumidifier fan/1 (FM3) and /2 (FM4) generate hot airflow inside the LU and • The dehumidifier control has two processes; a dehumidifier fan heater pre-drying and the temperature limit- reduce moisture in order to prevent jam of coated paper due to dampness. ing dehumidification control. The first one (pre-drying) is made with HTR3 , FM3 and FM4. Once the target temperature rise is achieved, the pre-drying process is finished and further dehumidification control limiting the temperature is carried out only by HTR3. • The dehumidification control is carried out according to the temperature inside the tray detected by the • Feeding paper from the LU cannot be made while the dehumidification control being performed. (this can temperature sensor (TEMS), and continued until the target temperature rise is achieved. be allowed by changing DIPSW setting) B. Dehumidifier fan heater pre-drying control • The user setting menu has an option to activate pre-drying with the dehumidifier fan heater before printing • When the pre-drying with the dehumidifier fan heater is set not to be activated in the user setting menu, the every time the upper door is opened/closed. pre-drying before printing is carried out if the upper door is opened/closed and a change in remaining amount of paper is detected. • HTR3, FM3, and FM4 turn on when 56% or higher ambient humidity is detected by the temp/humidity sen- • FM3 and FM4 are turned on at regular intervals, and kept on for a specified time period. sor/1 (TEM/HUMS/1) of the main unit. C. Triggers for dehumidification control • When the sub power switch (SW2) is turned on with the dehumidifier fan heater setting set to [Automatic] or [On (compulsory)], and with the paper type set to coated paper. • After the upper door is opened/closed with the dehumidifier fan heater setting set to [Automatic] or [On (compulsory)], and with the paper type set to coated paper. • When the paper type is changed to coated paper from other paper type with the dehumidifier fan heater setting set to [Automatic] or [On (compulsory)]. • When the dehumidifier fan heater setting is changed to [Automatic] from [Off (compulsory)], or changed to [On (compulsory)]. D. Temperature limiting dehumidification control • After the pre-drying is finished, the HTR3 is turned on or off to keep the target temperature. Ambient humidity Target temperature rise in the tray Lower than 55% Not controlled 56 to 60% 6°C 61 to 65% 7°C 66 to 70% 8°C 71 to 75% 9°C Higher than 76% 10°C E. Conditions to stop the dehumidification control 26 • When other than coated paper is selected as the paper type while the control is in progress. • When the dehumidifier fan heater setting is changed to [Off (compulsory)] while the control is in progress.
Related documents
要求水準書 PDF
SERVICE MANUAL - Imcopex America
Ricoh PRIPORT JP730 User's Manual
HP-GL,HP-GL/2,Calcomp906/907 TIFF,CALS G4,HP
Minolta Di650 Service manual
Pitney Bowes DI200 User's Manual
Konica Minolta CF5001 Copier User Manual
Product Guide
d-Color P325/P330_EN
ISUCALCFS - ISU Judging System
3 - Olivetti
DPP 1200 System Setup Guide