Download - DairyNZ

Transcript
5
SYSTEM DESIGN
The third stage in developing a farm dairy effluent (FDE) system is to select
components and create detailed plans describing how the system will achieve the
design specifications. System specifications are also prepared, listing what the final
system will comprise of, and what it will be capable of achieving.
5.1
Land Application System Selection
A land application system must be selected that meets or exceeds all of the
requirements of the design specifications. Application depth and application intensity
are the key specifications likely to drive the selection process. However, the system
must also be suitable for the farming enterprise type, and meet any other client needs.
Special emphasis should be given to providing a system that is capable of a low
application intensity and a low application depth where soil and landscape features
dictate this as beneficial.
Because of the nutrient content of FDE, it is especially important for FDE irrigation to
be applied with high uniformity. Highly uniform application maximises the nutrient
benefit to pasture and avoids potential adverse effects on water quality.
Special emphasis should also be given to selecting components that are able to handle
the solids content of FDE without blockages.
Note the section on Special Considerations for the Application of Separated Solids.
Adjusting Application Depth for Uniformity
The design specification for application depth (Section 4.3) needs to be adjusted for
the application uniformity of the selected system. The application depth, adjusted for
uniformity, must still be less than the depth listed in the design specification. Make
this adjustment prior to preparing the final system specification.
An upper quartile distribution uniformity (DUuq) is recommended as a measure of
FDE land application uniformity. DUuq is a measure of uniformity that focuses on the
one quarter of the application area that receives the highest applied depth (Duq – see
Figure 4). Therefore, minimising DUuq means minimising over-application of FDE
while maximising the mean depth that can safely be applied.
DUuq is calculated by:
DUuq = Duq / Davg
(7)
where:
DUuq = Upper quartile distribution uniformity
Duq = Mean depth of FDE applied to the one-quarter of the area receiving the
greatest depth
Davg = Mean depth of FDE applied to the whole area
Farm Dairy Effluent (FDE) Design Code of Practice – September 2015
Page 24