Download Maintenance Manual
Transcript
16 10.3 The fault code from the SP1 Programmer : (More codes you can see on the hand programming SP1). When the fault exists, connect the SP1 programmer's connector directly to the controller SDRIVE or to the charging socket, using a special wiring adaptor. The fault will be displaed on the SP1 programmer display. Table 1: Fault Code 0300 0815 0A00 0E08 0E07 1501 1502 1600 1601 1E08 1E09 1E0A 2C00 2F01 2F01 3100 3B01 3D02 3D03 4401 5300 All the others Action to troubleshoot Check the tiller & throttle wiring to the controller, then retest Check the tiller & throttle wiring to the controller, then retest Check the sleep mode parameter is set correctly, then retest Check the tiller & throttle wiring to the controller, then retest Check the tiller & throttle wiring to the controller, then retest Check the solenoid brake’s wiring & connections to the controller, then retest Check the solenoid brake’s wiring & connections to the controller, then retest Check the batteries’ wiring & connections to the controller, then retest Also possible a condition of high load driving downhill. Check the batteries’ wiring & connections to the controller, then retest Check the wiring & connections to pin 4 of the programming socket, then retest Check the wiring & connections to pin 6 of the 14 way tiller connector, then retest Inhibit 2 - check EMB manual brake micro switch. N/A for Breeze C. Check the batteries’ wiring & connections to the controller, then retest Check the throttle is not displaced on start-up, or does not return to natural condition , then retest Check the tiller & throttle wiring to the controller, then retest Battery connected whilst scooter is switched on. Turn off, wait 10 seconds, then retest Check the motor wiring & the connections to the controller, then retest Check the motor wiring & the connections to the controller, then retest Check the motor wiring & the connections to the controller, then retest Internal controller fault. Replace the controller (Make sure for the parameters setup). Programmable parameter changed. Turn the scooter off, then ON again, then retest Check all wiring & connections to the controller, then retest Table 2: No power to programmer No power to programmer Scooter drives slowly Scooter drives slowly Scooter drives slowly Status indicator does not light Reverse alarm does not sound Reverse alarm does not sound Reverse alarm does not sound Scooter will not drive in reverse Scooter will not drive in reverse Check the wiring & connections to the batteries, then retest Check the wiring & connections to the programmer, then retest Check the controller is programmed correctly, then retest Check the speed limiting function is not active e.g. seat raised, then retest Check the solenoid brakes are not jammed, then retest Check the wiring & connections to the status indicator, then retest Check the wiring & connections to the buzzer then retest Check the buzzer is working correctly, then retest Check the scooter is programmed correctly then retest Check the tiller wiring & connections, then retest Check the reverse switch is working correctly, then retest C:\Users\avner\Desktop\holland conference\Breeze C\9-------------------------MAINTENACE\3 -------------- Service Manaul\Service manual Eng\Breeze C Maintenance (19-7-2013) PRC4014b.doc