16
10.3
The fault code from the SP1 Programmer :
(More codes you can see on the hand programming SP1).
When the fault exists, connect the SP1 programmer's connector directly to the controller
SDRIVE or to the charging socket, using a special wiring adaptor.
The fault will be displaed on the SP1 programmer display.
Table 1:
Fault Code
0300
0815
0A00
0E08
0E07
1501
1502
1600
1601
1E08
1E09
1E0A
2C00
2F01
2F01
3100
3B01
3D02
3D03
4401
5300
All the others
Action to troubleshoot
Check the tiller & throttle wiring to the controller, then retest
Check the tiller & throttle wiring to the controller, then retest
Check the sleep mode parameter is set correctly, then retest
Check the tiller & throttle wiring to the controller, then retest
Check the tiller & throttle wiring to the controller, then retest
Check the solenoid brake’s wiring & connections to the controller, then retest
Check the solenoid brake’s wiring & connections to the controller, then retest
Check the batteries’ wiring & connections to the controller, then retest
Also possible a condition of high load driving downhill.
Check the batteries’ wiring & connections to the controller, then retest
Check the wiring & connections to pin 4 of the programming socket, then retest
Check the wiring & connections to pin 6 of the 14 way tiller connector, then retest
Inhibit 2 - check EMB manual brake micro switch.
N/A for Breeze C.
Check the batteries’ wiring & connections to the controller, then retest
Check the throttle is not displaced on start-up, or does not return to natural condition ,
then retest
Check the tiller & throttle wiring to the controller, then retest
Battery connected whilst scooter is switched on. Turn off, wait 10 seconds, then retest
Check the motor wiring & the connections to the controller, then retest
Check the motor wiring & the connections to the controller, then retest
Check the motor wiring & the connections to the controller, then retest
Internal controller fault. Replace the controller (Make sure for the parameters setup).
Programmable parameter changed. Turn the scooter off, then ON again, then retest
Check all wiring & connections to the controller, then retest
Table 2:
No power to programmer
No power to programmer
Scooter drives slowly
Scooter drives slowly
Scooter drives slowly
Status indicator does not light
Reverse alarm does not sound
Reverse alarm does not sound
Reverse alarm does not sound
Scooter will not drive in reverse
Scooter will not drive in reverse
Check the wiring & connections to the batteries, then retest
Check the wiring & connections to the programmer, then retest
Check the controller is programmed correctly, then retest
Check the speed limiting function is not active e.g. seat raised, then retest
Check the solenoid brakes are not jammed, then retest
Check the wiring & connections to the status indicator, then retest
Check the wiring & connections to the buzzer then retest
Check the buzzer is working correctly, then retest
Check the scooter is programmed correctly then retest
Check the tiller wiring & connections, then retest
Check the reverse switch is working correctly, then retest