Transcript
Operator's Manual Second Edition • Second Printing OPERATING INSTRUCTIONS Fall Protection After Each Use Personal fall protection equipment (PFPE) is required when operating this machine. 1 Select a safe parking location—firm level surface, clear of obstruction and traffic. All PFPE must comply with applicable governmental regulations, and must be inspected and used in accordance with the PFPE manufacturer’s instructions. Charging the Batteries Use the engine or the AC battery charger to recharge the batteries. Charging the Batteries with the Engine 2 Retract and lower the boom to the stowed position. 3 Rotate the turntable so that the boom is between the non-steer wheels. 4 Turn the key switch to the off position and remove the key to secure from unauthorized use. 5 Chock the wheels. 6 Charge the batteries (if necessary). Running the engine will automatically charge the batteries. At high idle, the engine supplies enough power for charging and for machine functions. At low idle, machine functions will use battery power. All lift and drive functions can be operated while the engine is running. The battery charge indicator will reset when the engine has been turned off for 2-3 minutes. Charging the batteries with the engine does not fully charge the batteries. Periodically, use the AC battery charger to fully charge the batteries. Charging the Batteries with the AC Charger Be sure the engine is not running. Use the AC battery charger included with the machine for overnight charging. The charger shuts off automatically. Periodically, use the AC battery charger to fully charge the batteries. 26 Genie Z-45/25 Bi-Energy & Genie Z-45/25J Bi-Energy Part No. 82596