38 • CHAPTER ONE
REDUCING VALVES
Multistage Reducing Valves
Single-Stage Reducing Valve
Multistage reducing valves are simply two
or more single-stage reducing valves in series
with one another. Figure 1-36 shows the component parts of this reducing valve. The first
stage reduces the cylinder to an intermediate
pressure of approximately 200 psi. The second
stage then reduces the pressure to the desired
working pressure, usually 50 psi. Each stage
operates independently from the other.
The addition of the additional stage allows
more precise regulation of pressure and a
greater flow rate than is possible with a singlestage reducing valve. Common applications of
multistage reducing valves include powering
of mechanical ventilators. These applications
require high flows and a stable pressure
source.
A single-stage reducing valve reduces the
pressure from the cylinder to a working pressure in one step or stage. All reducing valves
operate by using two opposing forces, spring
tension and gas pressure separated by a flexible diaphragm. Figure 1-34 illustrates the component parts of a single-stage reducing valve
and its operation. Gas pressure in the cylinder
displaces the diaphragm upward. When gas
pressure and spring tension are equal, the
diaphragm is flat, closing the poppet valve.
As the pressure within the chamber drops,
spring tension forces the diaphragm down,
opening the poppet valve. This cycle repeats
itself with the diaphragm oscillating back and
forth, opening and closing the poppet valve.
Spring tension determines the outlet pressure
from the reducing valve. The tension may be
fixed or adjustable depending on the reducing
valve’s construction. If the tension is adjustable, there is usually a screw provided that
will allow adjustment of the tension against
the diaphragm.
Modified Single-Stage
Reducing Valve
The modified single-stage reducing valve
is similar to the single-stage reducing valve.
The difference between the two is that the
modified single stage reducing valve has a
poppet closing spring in addition to the spring
above the diaphragm. Figure 1-35 illustrates
the component parts of this reducing valve.
The poppet closing spring allows the poppet
valve to open and close faster, providing
greater flow rates.
Figure 1-34 Functional diagram of a single-stage
reducing valve.
Reducing Valve Safety Features
Several safety features are incorporated
into the design of reducing valves. These
include pressure relief valves, or pop-off
valves, and indexing of the inlet and outlet.
Each stage of a reducing valve is required
to have a safety relief valve in the event that
excess pressure develops within the stage. The
safety relief will exhaust excessive pressure
before the reducing valve housing bursts.
The inlet of the reducing valve is indexed
with either American Standard indexing or the
Pin Index Safety System indexing. Both of
these systems were developed by the Compressed Gas Association and discussed earlier
in this chapter.
The outlet of the reducing valve uses
Diameter Indexed Safety System threads. This
safety system was also discussed earlier in this
chapter.
Figure 1-35 Functional diagram of a modified
single-stage reducing valve. Note the addition of a
poppet closing spring.
Copyright 2005 Thomson Learning, Inc. All Rights Reserved.