QSpecifications
Water chilling unit (Water cooled type)
Model C7-UWJ2650B5Y
☆Cooling
Item
Capacity
(50/60Hz)
kW
Chilled water
flow rate
(50/60Hz)
R/min
Pressure drop
(50/60Hz)
R/min
C7-UWJ3350B5Y
CUW120A5Y
CUW240A5Y
236/265
300/335
355/400
760/800
677/760
860/960
1018/1147
2178/2294
1266/1449
2550/2910
841/960
1064/1214
3 phase 380, 400, 415V/400, 440 VAC 50/60Hz
3 phase 380V, 50Hz
Control power source
Single phase 200 VAC 50/60Hz
220VAC 50/60Hz
Type
Water chilling unit (Water cooled type)
Exterior
External
dimensions
lvory white (5Y7.5/1)
H×W×D
mm
Model
Type
Motor output×No.of units
kW
1310×2835×900
1525×2785×995
1525×2840×980
2180×2855×1455
ZH3LSFYE/
ZH5MLFYE/
ZH3LSFYB
ZH5MLFYB
Semi-hermetically sealed single scroll type
ZH5LLFYE/
ZH5LLFYB
30×2
37×2
40×2
90×2
CXC2120-1
CXC2420-14
CF4520-C12
–
start
Heat exchanger
on water side
Starting system
ZH9SLFCYE
Semi-hermetic single screw type
Model
CXC1920
Type
Shell and cross fine tube type
No. of units
2
Evaporator
Compressor
Power source
Model
DHG2724
Type
Shell and HI-X tube type
Dry Expansion shell and Hi-x Tube Type
No. of units
1
2
DHG3222
Refrigerant control
Thermal expansion valve
Thermostat
Electronic thermostat for chilled water
Capacity control
%
Foam polyethylene
Protection device
See page 13
Refrig- Name
erant Charge
R22
16×2
20×2
24×2
60×2
10×2
SUNISO 4GSD
Refriger- Name
ation oil Charge
Pipe connections
DHD4020-C24
100-70-40-20-0
Insulation material
kg
DHG3224
R
10×2
14×2
Condenser water inlet/outlet
PT3 Internal thread
PT4 Internal thread
6B flange (connect to φ159 tube)
Chilled water inlet/outlet
4B Flange (JIS10K)
5B Flange (JIS10K)
Inlet 6B flange (connect to φ 159 tube)
Outlet 5B flange (connect to φ 140 tube)
Drain outlet
PT1 Internal thread for chilled water, PT11/4 Internal thread for cooling water
Weight (operating weight)
kg
7.5×2
1395(1500)
1790(1925)
1930(2085)
Instruction manual, warranty card, fuse, foundation bolt, vibro-isolating pad, warning sign.
Standard accessories
4880(5380)
Operation manual, fuse, warranty, mating flange
★Heating
[In case of modified heat-pump]---Only the specifications different from standard specifications are indicated.
Capacity
Hot water
flow rate
Chilled water
flow rate
(50/60Hz)
kW
277/319
350/403
422/485
838/985
(50/60Hz)
R/min
795/914
1004/1156
1197/1380
2405/2755
(50/60Hz)
R/min
356/401
452/509
535/605
1055/1210
Hot water thermostat
Electronic thermostat for chilled water
(Notes)
☆1: The values shown are based on leaving chilled water outlet temperature of 7°C, inlet/outlet temperature difference of 5°C, and condenser water
inlet temperature of 30°C D.B.
★2: The values shown are based on leaving hot water outlet temperature of 45°C, inlet/outlet temperature difference of 5°C, and chilled water inlet
temperature of 15.5°C D.B.
<<WRONG>>
HDSE08-1_フォント置換8-.indd Sec1:5
5
2011/05/26 8:57:12