Download here - Totaline
Transcript
FILE NO. SVM-05027 No. 6 Part name Cross flow fan Procedures 1) Remove the front panel, electrical part, horizontal louver and the heat exchanger with the procedure 4. 2) Remove 2 screws of the band motor (L) and other 2 screws of the band motor (R) and then remove the cross flow fan. 3) Loosen the set screw of the cross flow fan then disconnect the fan and the fan motor. Notice For position of the fan motor connector and drawing out of the lead cables, refer to the procedure 5. Fix the cross flow fan with the set screw at the position where the gap between the back body and the right surface of the cross flow fan is 4.5 mm. Remarks 2 2-Screws (R) 2 2-Screws (L) 4.5 mm 3 Set screws 7 Base bearing 1) Remove the front panel, electrical part, horizontal louver, heat exchanger and the cross flow fan with the procedure 5 and 6 . 2) Remove the 2 screws fixing the base bearing. 3) Remove the bearing from the base bearing. If the housing protrudes from the base bearing, put the housing in position and attach the bearing to the base bearing. – 81 – 2 2-Screws