SCHEMATICS GROUND TO SCROLL HOUSING WH TO ECM BLWR MOTOR BK 9 CIRCUIT CONNECTOR TO MAIN HARNESS PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 BK WH WH WH OR GY BK BK OR WH PIN 3 PIN 4 PIN 2 PIN 1 GY PIN 4 PIN 5 VT PK PIN 1 PIN 2 PIN 3 INDUCTOR COIL (GUVA070,090,115 MODELS ONLY) GN PK ECM BLOWER MOTOR YL AUXILIARY LIMITS (SIDES OF BLOWER HOUSING) HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. LINE CUT FOR DEHUM CIRC NEUTRAL INTEGRATED CONTROL MODULE XFMR EAC LOAD WH LINE BK HUM W R PARK OFF 3 2 1 US SINGLE ON S1 TSTAT EAC HOT COOL S4 CFM BK Intell-Ignition ON OFF LINE 87 4321 87 4321 S3 XFMR TRANSFORMER HUM TWO HI HEAT C LO HEAT BLOWER ASSEMBLY SCHEMATIC AMV9/ACV9_____X* MODEL FURNACES This schematic is for reference only. Not all wiring is as shown above, refer to the appropriate wiring diagram for the unit being serviced. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 23