Download ELECTRICAL SYSTEM SECTION EL

Transcript
POWER WINDOW
System Description
System Description
NHEL0191
Power is supplied at all times
I from 40A fusible link (letter I, located in the fuse and fusible link box)
I to circuit breaker terminal 1
I through circuit breaker terminal 2
I to power window relay terminal 3,
I to front power window main switch terminal 4, and
I to front power window switch RH terminal 6.
With ignition switch in ON or START position, power is supplied
I through 10A fuse [No. 10, located in the fuse block (J/B)]
I to rear power window switch LH and RH terminal 7
I to smart entrance control unit terminal 27.
Ground is supplied to power window relay terminal 1
I through body grounds M9, M25 and M87.
Ground is supplied to rear power window switch LH terminal 8
I through body grounds B7 and B46 (with rear sunshade), or B12 (without rear sunshade).
Ground is supplied to rear power window switch RH terminal 8
I through body grounds B106 and B127.
The power window relay is energized and power is supplied
I through power window relay terminal 5
I to front power window main switch terminal 11,
I to front power window switch RH terminal 13,
I to rear power window switch LH and RH terminals 5.
MANUAL OPERATION
Front Door LH
GI
MA
EM
LC
EC
FE
AT
AX
SU
NHEL0191S01
NHEL0191S0101
Ground is supplied
I to front power window main switch terminal 5
I through body grounds M9, M25 and M87.
WINDOW UP
When the front LH switch in the front power window main switch is pressed in the up position, power is supplied
I to front power window regulator LH terminal 1
I through front power window main switch terminal 2.
Ground is supplied
I to front power window regulator LH terminal 3
I through front power window main switch terminal 3.
Then, the motor raises the window until the switch is released.
WINDOW DOWN
When the LH switch in the front power window main switch is pressed in the down position, power is supplied
I to front power window regulator LH terminal 3
I through front power window main switch terminal 3.
Ground is supplied
I to front power window regulator LH terminal 1
I through front power window main switch terminal 2.
Then, the motor lowers the window until the switch is released.
Front Door RH
NHEL0191S0102
Ground is supplied
I to front power window main switch terminal 5
I through body grounds M9, M25 and M87.
WINDOW UP
When the front RH switch in the front power window switch is pressed in the UP position, power is supplied
EL-261
BR
ST
RS
BT
HA
SC
IDX