Download DELTABOOSTER

Transcript
Service / Repair
E
Motor / Technical Data
The motor is protected against overload by a motor protection device (overload cut-out), which
is adjusted to the nominal power consumption at working pressure + 1 amp.
Class:
F
IP 45 (front cabinet closed)
Thermal switch (bimetalic type) mounted in the windings between 2 phases. Opens at 160
±10°C. Leads out of motor are marked 9 and 14.
Power absorption of motor:
Output of motor:
Rev. of motor at 1/1 load, 50 Hz:
Rev. of motor at 1/1 load, 60 Hz:
COSϕ of motor:
Efficiency of motor:
6.7 kW
5.5 kW
1,440 rev./min.
1,730 rev./min.
0.83
0.79
Motor leads assembled in terminals
placed in both sides of the
machine.
1 .6
3 .5
2 .4
2
9
1 4
2
5
4
3
L 1 L 2
L 3
Y
Y
M 1 1
2
L 1 L 2
L 3
Y
Y
6
M 1 1
Delta connection
1
9
1 4
Star connection
~
3 Mot. 112M
3909645 - 13
E INB AU IP 54
380/220
cos ϕ 0,85
12/21 A
1435 1/min 50 Hz
5,5 Kw
S1
Y/ 380-480/210-260V cos ϕ 0,86-0,77
11-10,5/20-18,5 A
1730 1/min 60 Hz
5,5 kw
S1
T h. Cl. F
WS K 160° C
EN
60034
T 11 224275H
17 kg
E R 4/4-76P-145
The motors are fitted with model tags of the 2 variant above.
DELTABOOSTER_GB01