Download Service Jack

Transcript
Parts List & Operating Instructions
Form No. 107191, Back of Sheet 1 of 2
No. 501294 Hydraulic Assembly
21
20
19
1
Item
No.
Part
No.
Qty.
Description
2
1
512958
1
Rod Assembly
j
501351
j 501299
j 10913
=j 201433
=j 509133
j 221278
sj 501804
1
1
1
1
1
1
1
sj
1
1
1
1
1
1
Retaining Ring
Retaining Wire
O-ring
Retaining Ring
U-Cup Seal
Plug
Ball Seat Screw
(torque to 130 in.•lbs.)
Ball
O-ring
Relief Screw
Pump Rod
U-cup
Pump Tube
(torque to 75 ft.•lbs.)
Crush Washer
Check Valve
Brass Backup Ring
Wear Ring
O-ring
Gland
(includes items 5, 6, & 18)
2
3
4
5
6
7
9
3
4
5
10
11
12
13
14
15
6
18
7
Note: Previous part nos.
509131 & 509132 have
been replaced by Item
18 (516432).
9, 10
11
12
17
13
16
15
14
16
17
18
19
20
21
12223
10268
sj 508931
501354
j 501397
501355
sj
j
501400
221281
=j 516432
j 501298
j 14739
501300
1
1
1
1
1
1
Parts marked with an asterisk (j) are included in
Seal Kit No. 501816.
Parts marked with a triangle (s) are included in
Pump Release Valve Repair Kit No. 501235.
Parts marked with a dagger (=) are included with
Item No. 1 – Piston Rod Assembly No. 512958.
Shaded areas reflect the last revisions
made to this document.
When you receive a repair parts kit, parts for all
models will be included. Use only the parts for your
jack; discard the other parts.
Bleeding Air from the System
Air can accumulate within a hydraulic system during shipment, or if the oil supply runs too low. This entrapped air causes
the jack to respond slowly or feel “spongy.” The following procedure bleeds air from the system.
1. Remove the jack from service, and place it on a level surface.
2. Open the release valve by turning the handle all the way counterclockwise (CCW).
3. Pump the handle six full strokes.
4. Close the release valve by turning the handle all the way clockwise (CW).
5. Pump the handle until the lift arm is fully extended.
6. Lower the lift arm by turning the handle all the way counterclockwise (CCW).
7. Test the jack for normal operation. If the lift pad doesn’t rise to the correct height, repeat Steps 2-6. If this doesn’t solve
the problem, call the OTC Technical Services Dept. at (800) 533-6127.