Download Installation Instructions
Transcript
TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODES Digit 3 Compressor and outdoor . f Low pressure and high pressure switches are closed. Open start circuit has been detected 4 times with 5 minute delay between each detection. Integrated control module diagnostic/status LED display shows the indicated code. Digit 2 Digit 1 L 6 Open Start Circuit Lockout 06 Compressor start winding is open. Failed compressor run capacitor. Faulty run capacitor wiring. Compressor not properly wired to control. Faulty compressor wiring. Check compressor; repair/replace as needed. Check run capacitor; replace as needed. Check wiring repair/replaced as needed. Turn power OFF prior to repair Must clear fault by cycling 24VAC to control. Replace with correct replacement part(s). START displays error message. Compressor and outdoor f . Low pressure and high pressure switches are closed. Integrated control module diagnostic/status LED display shows the indicated code. 0 7 Open Run Circuit 07 Compressor run winding is open. Compressor not properly wired to control. Faulty compressor wiring. Check compressor; repair/replace as needed. Check wiring; repair/replace as needed. Turn power OFF prior to repair. Fault will clear after 1 normal cycle. Fault may be cycling 24VAC to control. Replace with correct replacement part(s). L 7 Open Run Circuit Lockout 07 Compressor run winding is open. Compressor not properly wired to control. Faulty compressor wiring. Check compressor; repair/replace as needed. Check wiring; repair/replace as needed. Turn power OFF prior to repair. Must clear fault by cycling 24VAC to control. Replace with correct replacement part(s). L 8 Low Line Voltage 08 Low line voltage. Check circuit breakers and fuses. Verify unit is connected to power supply Turn power OFF prior to repair. Control detects line voltage less than 185 VAC. Fault will clear if line voltage increases above 185 VAC. displays error message. Compressor and outdoor . f Low pressure and high pressure switches are closed. Open run circuit has been detected 4 times with 5 minute delay between each detection. Integrated control module diagnostic/status LED display shows the indicated code. displays error message. Air conditioner/heat pump may appear to be operating normally. Compressor protector may be open (compressor and outdoor f Integrated control module diagnostic/status LED display shows the indicated code. VOLT rating plate. Correct low line voltage condition; contact local utility if needed. 21