PACKAGE COOLING SPECIFICATIONS
*PC13[36-60]M41C*
*PC1336M41C*
*PC1348M41C*
*PC1360M41C*
COOLING CAPACITY, BTUH
SEER / EER
VOLTAGE (NAMEPLATE)
AMPS
MIN CIRCUIT AMPACITY
MAX OVERCURRENT PROTECTION
COMPRESSOR TYPE
RATED LOAD AMPS
LOCKED ROTOR AMPS
HORSEPOWER
CONDENSER
RPM
FAN MOTOR
FULL LOAD AMPS
LOCKED ROTOR AMPS
BLADE DIAMETER (INCHES)
CONDENSER
NUMBER OF BLADES
FAN
FACE AREA (SQ. FT.)
CONDENSER
NUMBER OF ROWS
COIL
FINS PER INCH
EVAPORATOR HORSEPOWER - NO. OF SPEEDS
FULL LOAD AMPS
BLOWER
LOCKED ROTOR AMPS
MOTOR
MOTOR SPEED TAP-COOLING EEM
RPM
EVAPORATOR DIAMETER X WIDTH (INCHES)
RATED SCFM COOLING
BLOWER
MAX EXTERNAL STATIC PRESS ("w.c.)
EVAPORATOR FACE AREA (SQ. FT.)
NUMBER OF ROWS
COIL
FINS PER INCH
FILTER SIZE *
GENERAL
INFORMATION DRAIN SIZE (INCHES)
EXPANSION DEVICE
REFRIGERANT CHARGE R410A (OZS.)
35,000
13 / 11
208/230-1
21.2
25.3
40
Scroll
16.7
79
1/4
1,075
1.4
2.9
22
3
8.77
2
27
1/3 - 3
3.06
4.1
High
910
10 x 9
1,080
0.5
4.55
4
14
25 x 25 x 1
¾"
0.070
70
45,500
13 / 11
208/230-1
27.1
32.1
50
Scroll
19.9
109
1/4
1,075
1.4
2.9
22
3
15.36
1
24
3/4 - 5
5.8
--T2
1,050
10 x 9
1,675
0.5
6.20
4
14
(2) 20 x 20 x 1
¾"
0.076
116
56,000
13 / 10.9
208/230-1
35.4
42.0
60
Scroll
26.4
134
1/4
1,075
1.4
2.9
22
3
21.04
2
16
1-5
7.6
--T2
1,050
10 x 9
1,750
0.5
6.20
4
14
(2) 20 x 20 x 1
¾"
0.087
195
POWER SUPPLY
CONDUIT KNOCKOUT SIZE (INCHES)
3/4, 1, 1-1/4
3/4, 1, 1-1/4
3/4, 1, 1-1/4
LOW VOLTAGE
CONDUIT KNOCKOUT SIZE (INCHES)
1/2
1/2
1/2
SHIPPING WEIGHT (LBS.)
OPERATING WEIGHT (LBS.)
365
355
435
425
445
435
COOLING
CAPACITY
UNIT
ELECTRICAL
SPECIFICATION
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
21