BFH / OPTIMA Profiling In the BFH/Optima Series system, the distance measuring devices (range finders) are rotated in a plurality of known positions by a stepper motor, so that they constitute optical scanners. The scanners, detecting the distances from a known position of a plurality of points on the object to be explored (the wheel rim) allows the spatial co-ordinates of each point detected to be obtained. For each scanner, the complete process is as follows: 1. Measuring the distance to the point hit. 2. Saving the distance measured at point 1 and the position of the distance measuring device at point 1. 3. Moving the laser range finder to the next known position. 4. Repeating steps 1 – 4 until the scan is complete. Based on these co-ordinates, it is possible to identify positions on the rim profile which are useful, and even in a certain sense optimum, for the application of balancing counterweights. The co-ordinates of these positions are calculated automatically and without contact. The complete weight position detection process is as follows: 1. 2. 3. 4. 5. 6. 7. Scan rim contour to determine typical rim parameters Compare current rim pattern with a set of stored rim patterns Select the best match stored rim pattern Pick pre-established weight locations associated with the best match pre-established rim pattern Calculate weight amount and display Allow the user to modify suggested weight location by moving the laser pointer “Learn” from experience Page 5-2 Effective 10/2007