EBS MARK II
TROUBLESHOOTING
4. ERROR MESSAGES OF THE SERVO DRIVE (FAULT 20)
A 10
Undervoltage in supply voltage
Check the voltage in the mains
A 20
Servo motor encoder failure
Check the proper connection of
connectors of the servo motor and if the
cable of the servo motor connection is
not damaged
A 32
Overvoltage
Check if the cable of the servo motor
connection is not damaged
A 33
Overvoltage in supply voltage
Check the voltage in the mains
Mechanical overloading
Check the proper connection of
connectors of the servo motor and if the
cable of the servo motor connection is not
damaged and if the sewing mechanism is
not mechanically blocked
E 50