Download 1 Features

Transcript
• Outdoor Units • R-410A • RZQS-B7V3
8
Wiring diagram
8-1
Wiring diagram
RZQS71-100BV3
Indoor
L
N
: Live
: Neutral
: Field wiring
: Protective earth (screw)
: Wire clamp
: Terminal
: Connector
8
NOTE 1.
1
Outdoor
: Relay connector
Colours
BLK: Black / ORG: Orange / BLU: Blue /
WHT: White / RED: Red / YLW:Yellow /
BRN: Brown / GRN: Green
ON
OFF
NOTES:
1. Refer to the optional manual, for connection wiring to
X6A.
2. Confirm the method of setting the selector switches
(DS1) by service manual. When the unit is shipped by
factory all switches are set to be off.
El. comp. assy front
A1P
A2P
BS1
C1-C2-C3
DS1
F1U
HAP (A1P)
HAP (A2P)
H1P (A1P)
Printed circuit board
Printed circuit board (INV)
Push button switch (forced def. / pump down)
Capacitor
Dip switch
Fuse (T6, 3A/250V)
Light emitting diode (service monitor green)
Light emitting diode (service monitor green)
Light emitting diode (service monitor red)
K1M(A2P)
K1R(A1P)
K2R(A1P)
K2R(A2P)
L1R
M1C
M1F
PS
Q1DI
R1-R2
R1T
Magnetic contactor
Magnetic relay (Y1S)
Magnetic relay (Y2S)
Magnetic relay
Reactor
Motor compressor
Motor fan
Power circuit
Earth leakage breaker (30mA)
Resistor
Thermistor (air)
R2T
R3T
R4T
R5T
S1PH
S1NPL
RC
TC
V1R
Thermistor (coil)
Thermistor (discharge pipe)
Thermistor (suction pipe)
Thermistor (power module)
Pressure switch (high)
Pressure sensor (low)
Signal receiver circuit
Signal transmission circuit
Power module
V2R-V3R
V1T
X6A
X1M
Y1E
Y1S
Y2S
Z1C, Z2C
Z3C, Z4C
Z1F
View A
Diode module
IGBT
Connector (Option)
Terminal strip
Expansion valve
4-way valve
Solenoid valve
Noise filter
Noise filter (with surge absorber)
2TW26736-1B
RZQS125BV3
Indoor
Outdoor
: Live
: Neutral
: Field wiring
: Protective earth (screw)
: Wire clamp
: Terminal
: Connector
NOTE 1.
L
N
: Relay connector
Colours
BLK: Black / ORG: Orange / BLU: Blue /
WHT: White / RED: Red / YLW:Yellow /
BRN: Brown / GRN: Green
ON
OFF
NOTES:
1. Refer to the optional manual, for connection wiring
to X6A.
2. Confirm the method of setting the selector switches
(DS1) by service manual. When the unit is shipped
by factory all switches are set to be off.
El. comp. assy front
A1P
A2P
BS1
C1-C2-C3
DS1
E1HC
F1U
F2U
F3U
HAP (A1P)
HAP (A2P)
H1P (A1P)
21
Printed circuit board
Printed circuit board (INV)
Push button switch (forced def. / pump down)
Capacitor
Dip switch
Crankcase heater
Fuse (T 6,3A/250V)
Fuse
Fuse (B 5A/250V)
Light emitting diode (service monitor green)
Light emitting diode (service monitor green)
Light emitting diode (service monitor red)
K1M(A2P)
K1R(A1P)
K2R(A1P)
K3R(A1P)
K4R (A1P)
L1R
M1C
M1F
PS
Q1DI
R1-R2
R1T
Magnetic contactor
Magnetic relay (Y1S)
Magnetic relay
Magnetic relay (E1HC)
Magnetic relay (Y2S)
Reactor
Motor compressor
Motor fan
Power circuit
Earth leakage breaker (30mA)
Resistor
Thermistor (air)
• Split Sky Air • Outdoor Units
R2T
R3T
R4T
R5T
S1PH
S1NPL
TC
V1R
Thermistor (coil)
Thermistor (discharge pipe)
Thermistor (suction pipe)
Thermistor (power module)
Pressure switch (high)
Pressure sensor (low)
Signal transmission circuit
Power module
V2R-V3R
V1T
X6A
X1M
Y1E
Y1S
Y2S
Z1C, Z2C
Z3C, Z4C
Z1F
Z1F
View A
Reactor box
Diode module
IGBT
Connector (Option)
Terminal strip
Expansion valve
4-way valve
Solenoid valve
Noise filter
Noise filter
Noise filter (with surge absorber)
2TW26746-1