Download DCEDRAIN D.vp
Transcript
4. Unplug connector from power cord and connect pump harness to power cord and machine connector (located near compressor), 5. Restore power to the unit and with the ON/OFF/BIN LEVEL control still in the OFF position, pour several quarts of water into the bin. The drain pump should turn on and pump the water out of the bin, perhaps cycling on and off several times during the process. Pump cycling is normal since the pump-out rate of the drain pump is greater than the rate of drain through the bin. 6. While the pump is discharging water, THOROUGHLY CHECK THE ENTIRE DRAIN SYSTEM FOR LEAKS. 7. Re-install unit into built-in or free-standing location. ENSURE THAT NO KINKS OCCUR IN WATER INLET OR DRAIN TUBING. 8. Restore potable water supply and manually advance the unit’s timer to the HARVEST position. Turn the ON/OFF/BIN LEVEL control knob ON to the required operating range setting for the application. Check unit for at least one cycle to ensure proper operation and to allow a final check for leaks of any kind. 9. Re-install control box cover and kick-plate. Conversion of a gravity drain system to a drain pump system is now complete. COMM NC R NO BK IF DRAIN PUMP IS INSTALLED IF DRAIN PUMP IS INSTALLED POWER IN EARTH GROUND DRAIN PUMP PRESSURE SWITCH GN/Y W 3 GN/Y W 2 COMM W BIN LEVEL CONTROL BIN LEVEL CONTROL COMPRESSOR BU CUBE SIZE CONTROL (INITIATE TIMER SWITCH) BK/W FAN MOTOR HOT GAS SOLENOID C NC R W W Y W W R Y DRAIN PUMP BU NC NO PUMP PRESSURE SWITCH ON SAFETY PRESSURE SWITCH OFF 1 CUBE SIZE CONTROL PUMP MOTOR BK N L1 BK BK SAFETY PRESSURE SWITCH NO BN W TIMER WATER R/W SOLENOID 6 1 2 C BK NC HARVEST TIME ADJUSTABLE FROM 120 TO 300 SEC. FACTORY SET TO 170 FAN MOTOR 6 NO 1 TIMER 2 WATER PUMP WATER SOLENOID W DRAIN PUMP MOTOR RELAY - CURRENT HOT GAS SOLENOID 1 S SWITCHES ON THIS UNIT SHOWN IN TIMED PORTION OF THE FREEZE CYCLE WITH DRAIN PUMP IN OPERATION M 1 3 OVERLOAD COMPRESSOR INSTALLATION INSTRUCTIONS 1. UNIT MUST BE INSTALLED AND IN ACCORDANCE WITH LOCAL CODES. 2. CONNECT A POTABLE WATER LINE TO 1/4 NPT ON WATER VALVE LOCATED IN THE FRONT ON THE MACHINE. 3. ROUTE 3/8" ID FLEXIBLE HOSE FROM LEFT FRONT OF M PER INSTRUCTIONS FOR DCE33PA IN SERVICE MANUAL. 4. CONNECT THE ELECTRICAL POWER CORD TO A PROPERLY WIRED AND GROUNDED RECEPTICAL. 3 ACHINE 5. BY TURNING THE ON/OFF SWITCH/BIN LEVEL CONTROL DIAL IN A CLOCKWISE DIRECTION TO APPROXIMATE OPERATING RANGE MARKING. UNIT IS NOW IN AUTOMATIC OPERATION. 17-3353-01