4. Unplug connector from power cord and connect pump harness to power cord and machine
connector (located near compressor),
5. Restore power to the unit and with the ON/OFF/BIN LEVEL control still in the OFF position, pour
several quarts of water into the bin. The drain pump should turn on and pump the water out of the
bin, perhaps cycling on and off several times during the process. Pump cycling is normal since the
pump-out rate of the drain pump is greater than the rate of drain through the bin.
6. While the pump is discharging water, THOROUGHLY CHECK THE ENTIRE DRAIN SYSTEM FOR
LEAKS.
7. Re-install unit into built-in or free-standing location. ENSURE THAT NO KINKS OCCUR IN
WATER INLET OR DRAIN TUBING.
8. Restore potable water supply and manually advance the unit’s timer to the HARVEST position.
Turn the ON/OFF/BIN LEVEL control knob ON to the required operating range setting for the
application. Check unit for at least one cycle to ensure proper operation and to allow a final check for
leaks of any kind.
9. Re-install control box cover and kick-plate. Conversion of a gravity drain system to a drain pump
system is now complete.
COMM
NC
R
NO
BK
IF DRAIN PUMP
IS INSTALLED
IF DRAIN PUMP
IS INSTALLED
POWER IN
EARTH GROUND
DRAIN PUMP
PRESSURE
SWITCH
GN/Y
W
3
GN/Y
W
2
COMM
W
BIN
LEVEL
CONTROL
BIN LEVEL
CONTROL
COMPRESSOR
BU
CUBE SIZE
CONTROL
(INITIATE
TIMER
SWITCH)
BK/W
FAN
MOTOR
HOT GAS
SOLENOID
C
NC
R
W
W
Y
W
W
R
Y
DRAIN
PUMP
BU
NC
NO
PUMP
PRESSURE
SWITCH
ON
SAFETY
PRESSURE
SWITCH
OFF
1
CUBE SIZE
CONTROL
PUMP
MOTOR
BK
N
L1
BK
BK
SAFETY
PRESSURE
SWITCH
NO
BN
W
TIMER
WATER
R/W
SOLENOID
6
1
2
C
BK
NC
HARVEST TIME
ADJUSTABLE
FROM 120 TO 300 SEC.
FACTORY SET TO 170
FAN
MOTOR
6
NO
1
TIMER
2
WATER
PUMP
WATER
SOLENOID
W
DRAIN
PUMP
MOTOR
RELAY - CURRENT
HOT GAS
SOLENOID
1
S
SWITCHES ON THIS UNIT
SHOWN IN TIMED PORTION
OF THE FREEZE CYCLE
WITH DRAIN PUMP IN OPERATION
M
1
3
OVERLOAD
COMPRESSOR
INSTALLATION INSTRUCTIONS
1. UNIT MUST BE INSTALLED AND IN
ACCORDANCE WITH LOCAL CODES.
2. CONNECT A POTABLE WATER LINE TO 1/4 NPT ON WATER
VALVE LOCATED IN THE FRONT ON THE MACHINE.
3. ROUTE 3/8" ID FLEXIBLE HOSE FROM LEFT FRONT OF M
PER INSTRUCTIONS FOR DCE33PA IN SERVICE MANUAL.
4. CONNECT THE ELECTRICAL POWER CORD TO
A PROPERLY WIRED AND GROUNDED RECEPTICAL.
3
ACHINE
5. BY TURNING THE ON/OFF SWITCH/BIN LEVEL
CONTROL DIAL IN A CLOCKWISE DIRECTION
TO APPROXIMATE OPERATING RANGE MARKING.
UNIT IS NOW IN AUTOMATIC OPERATION.
17-3353-01