6. TROUBLESHOOTING
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
1
Power Source.
YES
Remove PTC-Starter
from Compressor and
measure voltage
between Terminal C of
Compressor and
Terminal 5 or 6 of PTC.
(Rated Voltage
–10%)?
No Voltage.
OLP disconnected?
2
YES
Reconnect.
NO
5
Check connection
condition.
Replace OLP.
Applied voltage isn’t
in acceptable range.
(115V –10%)
Advise customer that
power supply needs to be
checked by an electrician.
The range of resistance is between 1~50½(ok)
Check
resistance of
Motor
Compressor.
Check resistance
between M-C, S-C and
M-S in Motor
Compressor.
3
Check
resistance of
PTC-Starter.
Check resistance of
two terminals in
PTC-Starter.
At normal temperature
6.8? +20: OK
4
Check OLP.
Check resistance of two
terminals in OLP.
If power conducts: OK
If not: NG
5
Check
starting state.
Check the power supply
under load.
(Compressor attempting
to re-start after being off
for 5 minutes).
2
5
Open or short
Replace
Compressor.
Supply
voltage rating
with –10%.
YES
3
Did
compressor
start?
4
YES
NO
NO
- 20 -
3
5
Compressor
is OK
Replace the
compressor
1