Download TROUBLESHOOTING NUCLEAR INSTRUMENTS

Transcript
-313.3.8a
Chapter 3
Double Pulse Generator
The simultaneous positive and negative o u t p u t s deliver 2 w a t t s into
50 ohms.
Pulse a m p l i t u d e , w i d t h , delay and r e p e t i t i o n rate are continuously
variable.
Other c a p a b i l i t i e s include single or double pulse operation,
external
triggering
synchronous or
asynchronous
gating,
reference
trigger o u t p u t s , sine wave triggering, and manual
single pulse operation.
Specifications:
repetition rate
10 Hz - 10 MHz
external trigger
_+ 0.25V, 20nsec min, 50 Hz - 10 MHz
sin. IVrms manual cycle
synchronous, asynchronous gating possibilities
advanced trigger
+ 1.7 V min, 15ns
reference trigger
+ 2 V rain, 15ns
pulse mode - single:
- double
one output pulse at the end of the delay
period
two identical pulses per cycle first
after the reference trigger, second
after the selected delay
pulse delay
40 ns - 10 ms
pulse width
40 ns - 10 ms
pulse height
0.5 - 10V (50 )
ABC
(51)