Download Walker Property Evaluation Services

Transcript
Inspection Address:
2318 Buena Vista Avenue, Belmont, CA 94002
Inspection Date/Time:
11/25/2008 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Electrical
• ¬We observed non-ground contact rated electrical wiring that is used improperly in an underground installation
• qThere several improperly terminated electrical wires within the crawlspace
Exterior
Wall Covering
Wall Covering Observations
• ¬Portions of the exterior cladding appear weathered and should be painted and or sealed
Exterior Features
Steps and Handrails
• ¬Portions of the stair framing or stringers appear deteriorated at grade
Carport
• qPortions of the carport roof framing appear moisture damaged
General Exterior Electrical Comments
• qThere are one or more areas where improperly protected or non-exterior rated components are installed
Storage Enclosure
• ¬The exterior door appears moisture damaged at the base and should be serviced or replaced as necessary
Exterior - Detached Building
Wall Covering
Wall Covering Observations
• ¬Portions of the exterior cladding appear weathered and should be painted and or sealed
• ¬Portions of the exterior cladding are installed with improper clearances to grade and should be serviced
Exterior Features
Fascia and Trim
• ¬Several areas of the exterior wood eaves trim etc appear weathered and should be serviced
Roof/Attic
Attic
Ventilation
• ¬We noted one or more improperly sealed vent screens openings that should be serviced
Electrical
• qWe noted attic insulation in contact with several recessed lighting fixtures
• qWe noted one or more improperly terminated electrical cables and or wires in the attic
• ¬There are several open electrical junction boxes that should be sealed
• ¬We noted one or more apparently damaged light fixtures within the attic that should be serviced
Plumbing
Potable Water Pipes
Copper and Galvanized Pipes
• qGalvanized and copper pipes have been directly and improperly connected that the left exterior
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of Walker Property Evaluation Services. Copyright 2008.
Inspection Overview - Page 2