Download VM3 Manual
Transcript
The default conductance formula is as follows: $RCHLNG ¥ $WIDTH ¥ $K ¥ $UCTOCOND $COND = -------------------------------------------------------------------------------------------------------------------$STOP – $SBOT Where: $COND is the Conductance $RCHLNG is the reach length of the river line in each grid cell $WIDTH is the River Width in each grid cell $K is the Riverbed Kz $UCTOCOND is the conversion factor for converting the $K value to the same L and T units used by $COND $STOP is the Streambed Top elevation $SBOT is the Streambed Bottom elevation If the Use default conductance formula option is turned off, the fields used for calculating the Streambed Conductance value (Width and Streambed Kz) are removed from the table and the Streambed Conductance field becomes a read/write field where any value or alternate formula may be entered. If the Calculate stream stage option is selected, the Stream data input window will also prompt for the Roughness (Manning’s roughness coefficient) of the stream channel. The Slope of the stream channel is not entered because it is automatically calculated using the change in the Streambed Top elevation from one grid cell to the next. For details on entering boundary condition data refer to the section Entering Flow Boundary Condition Data on page 106. For details on using mathematical formulas and array variable to define boundary condition data refer to the section Using Mathematical Formulas and Array Variables on page 108. For details on importing transient boundary condition data refer to the section Importing Transient Boundary Condition Data on page 110. For details on erasing boundary conditions refer to the section Erasing Flow Boundary Conditions on page 116. For details on copying boundary condition data refer to the section Copying Flow Boundary Conditions on page 116. Boundary Conditions 127