Download User manual
Transcript
D1ed4-IT-UK-uso 16-09-2008 16:33 Pagina 10 Standard parameters description Configuration parameters, shown in the parameters table, have been divided into groups with homogeneous functionalities. The parameters described hereafter are in the same order as they are listed in the parameters table. Configuration IL Digital input function Table 1 Not used PV measure hold Auto/Man 1st stored Setpoint 2st stored Setpoint Run Timer unit Mnemonic code A1S.P A2S.P A3S.P SL. u SL. d SP. L SP. H SP. 1 SP. 2 SP Table 2 A (Ampere) bar psi Rh pH A1S.P AL1 threshold A2S.P AL2 threshold A3S.P AL3 threshold Alarm occurrences of OP1,OP2 and OP3 outputs, respectively linked to AL1, AL2 and AL3. The range of the alarm threshold correspond to the whole span and it is not limited by the SP Setpoint span. Setpoint ramp up SL. d Setpoint ramp down This parameter specifies the maximum rate of change of the SP in digit/min. The SP value is reached according to the configured rate of change. The new SP value is called "Target SP" (available via serial communications). Example: Target Setpoint = 350°C SP 350°C Setpoint change 250°C SL. u 10 digit/minutes Initial Setpoint 0 t = 10 minutes Digital input function IL Instrument position Engineering unit No. of decimals Low range High range Communications protocol Baud rate Enhanced Overshoot management Units see table 1 Alone/left side/central/right side see table 2 0...3 -999...9999 engineer. units -999...9999 engineer. units Modbus/Jbus 1200, 2400, 4800, 9600 baud 0.2...5.0 Parameter description Range AL1 alarm threshold AL2 alarm threshold AL3 alarm threshold Setpoint ramp up Setpoint ramp down Setpoint low range Setpoint high range 1st stored Setpoint 2nd stored Setpoint Setpoint Mnemonic code hy tune P.b. t.i. t.d. O.C. M.res d.err t.c. OP. H S.Out dbnd r.C.G.a hy. C t.c. C OP. HC A.Man PV range PV range PV range OFF/0.1...999.9 OFF/0.1...999.9 low range...SP. H S.P L...high range PV range PV range PV range Parameter description Setpoint low limit Factory setting not used Alone none 0 Low range High range Modbus 9600 0.5 Notes Linear scales only Minimum range 100 digit P.I.D. only Factory setting 0 0 0 inhibited inhibited low range high range ---------- Notes not enabled if the controller has been configured with alarm not active or with sensor break alarm With OFF the new Setpoint is reached immediately after being entered. Units 0.1...10.00 % PV range Start/stop 0.5...999.9 % PV range OFF/0.1...100.0 min OFF/0.01...10.00 min 0.01...1.00 0.0...100.0 % ouput OFF/0.01...10.0 digit 1...200 s 10.0...100.0 % ouput 0.0...100.0 % ouput -10.0...10.0 % ouput 0.1...10.0 0.1...10.0 % PV range 1...200 s 10.0...100.0 % ouput Auto/Man Parameter description AL1 hysteresis Alarm Latching and Blocking LBA delay Soft-start output value Soft-start activation time Filter time costant Input shift Communications address CT primary high range Instrument range SP. H Setpoint range 1st stored SP Range Units 0.1...10.0 % range none/Ltch/Bloc/LtbL OFF / 1...9999 s OFF/0.1...100.0 % ouput 1...9999 s OFF/1...30 s OFF/-60...+60 digit 1...247 OFF/1...200 A Automatic tune The Fuzzy Tuning determines automatically the best method to use to calculate the P.I.D. term, according the process conditions. SP Setpoint change End of the tuning operating and setting of the new calculated terms Control output This type is selected when, at the start of the autotune operation, the PV is far from the Setpoint of more than 5% of the span. This method has the big advantage of fast calculation, with a reasonable accuracy in the term calculation. Setpoint change Method 2: Natural frequency Tuning start End of the tuning phase and setting of the new calculated terms SP. 2 2nd stored SP Values of the two Setpoints, that are activated by mean of digital input or communications parameters. If configured with “Tracking”, the previous Local Setpoint value will be lost, when the stored Setpoint is selected. If configured with “Stand-by” the Local Setpoint value will not be lost, when the Stand-by Setpoint is selected. It will operate again when back to Local. 5.0 5.0 1.00 1.00 50.0 inhibited 20 100.0 0 0.5 1 0.5 20 100.0 Auto Notes Setting 1 is disabled Without integral time Algorithm type ON - OFF P.I.D. Time proportional only -100.0...+100.0 Heat/Cool ON/OFF only Time proportional only P.I.D. only Heat/ Cool Factory setting 0.5 none inhibited 0.5 1 inhibited inhibited 247 100 Notes The same parameters are available for AL2 and AL3 alarms OFF = sensor break t.mod = OFF only ONly if sT.OP different than OFF Control mode PV variable Setpoint High limit Factory setting 0.5 Alarm and Auxiliary Mnemonic code A1hy A1LB t.Lba St.OP St.tn t.Fil in.Sh Addr Ht.F.S. Tuning start Sepoint high limit Low / high limit of the Setpoint value. SP. L engineer. units engineer. units engineer. units digit/min digit/min engineer. units engineer. units engineer. units engineer. units engineer. units Range Control output hysteresis Tune run/stop Proportional band Integral time Derivative time Overshoot control Manual reset Error dead band Cycle time Control output high limit Control output safety value Dead band Cool relative gain Cool output hysteresis Cool cycle time Cool control output high limit Auto/man selection Method 1: STEP respose Setpoint Low limit Units tune SL. d SP. 1 Range t When the parameter is OFF, this function is disabled and the new Setpoint is reached immediately after being entered. SL. u Parameter description Control mode Setpoint (SP) SL. u Configuration Mnemonic code IL PStr Unit Sc.dd SC.Lo Sc.Hi Prot baud O.C.rb Setpoint Engineering units C (degree Centigrade) °F (degree Fahrenheit) - None mV (millivolt) V (Volt) mA (milliampere) Table of standard parameters Control output This type is selected when the PV is close to the SP Setpoint. This method has the advantage of a better accuracy in the term calculation with a reasonable speed calculation. 2 p.B. Proportional band This parameter specifies the proportional band coefficient that multiplies the error (SP - PV) t.i. Integral time It’s the integral time value, that specifies the time required by the integral term to generate an output equivalent to the proportional term. When OFF the integral term is not included in the control algorithm. t.d. Derivative time It is the time required by the proportional term P to repeat the output provided by the derivative term D. When OFF the derivative term is not included in the control algorithm. O.C. Overshooot control This parameter specifies the span of action of the overshoot control. Setting lower values (1.00 —> 0.01) the overshoot generated by a Setpoint change is reduced. The overshoot control doesn’t affect the effectiveness of the P.I.D. algorithm. Setting 1, the overshoot control is disabled. OC.rb Enhanced overshoot management Configuration parameter. Defines a zone across the Setpoint where the P.I.D. algorithm is not affected by overshoot control. Setting range 0.2... 5.0. Default value 0.5. If OC.rb < 1 the non influenced zone is inside the proportional band, if OC.rb > 1 the non influenced zone is outside the proportional band Reducing the OC.rb value causes higher overshooting effect and longer times in reaching the Setpoint.