Download here - Primet
Transcript
c* = M⋅ with, c* M %drift 100 0.1 V1 %drift ⋅ 0.1 100 V1 (15) = total mass concentration in water layer (mg/m3 = µg/L) = dose applied (g a.i./ha) = percentage of spray drift (%) = correction factor to convert from percentage to fraction = correction factor to convert from g/ha to mg/m2 = ratio between volume of watercourse and surface (m) The ratio between volume and water surface in 1 m length of watercourse is calculated with: V1 = h( b + h ⋅ s 1 ) ⋅ 1 (b + 2 ⋅ h ⋅ s 1 ) ⋅ 1 with: V1 h b s1 1 (16) = ratio between volume and surface of watercourse (m) = water depth of watercourse (m) = bottom width of watercourse (m) = side slope, horizontal/vertical (-) = length of watercourse Then the momentary concentration of a single application, PEC1water, of a single application is calculated via: c* 1 + ss ⋅ m om ,ss ⋅ K om (Adriaanse, 1996) with, PEC1water = momentary water concentration from a single application (µg/L) c* = total mass concentration in water layer (µg/L) ss = mass concentration of suspended solids in water (kg/L) mom,ss = mass fraction organic matter in suspended solids (g/g) Kom = sorption coefficient on organic matter (L/kg) PEC 1water = (17) If Kom is not available it can be calculated from the more available Koc using Eq. (18): K oc 1.724 (FOCUS, 2001) with, Kom = sorption coefficient on organic matter basis (L/kg) Koc = sorption coefficient on organic carbon basis (L/kg) K om = Alterra-Report 1185 (18) 21