Download Manual - EtherWAN

Transcript
Hardened Web-Smart High Power PoE Ethernet Switch
LED
State
Power1
Power2
Power3
Steady
Power on.
Off
Power off.
Steady
Power redundant system failure occurred.
Off
Power redundant system failure is not occurred.
Fault
Indication
10/100Base-TX, 100Base-FX/BX
Link/ACT
10/100
PoE
Steady
A valid network connection established.
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady
Valid port connection at 100Mbps.
Off
Valid port connection at 10Mbps.
Steady
Powered Device (PD) is connected.
Off
Powered Device (PD) is disconnected.
Power Input Assignment
Power3
Power2
Power1
55VDC
+
55VDC
-
Power Ground
+
55VDC
-
Power Ground
DC Jack
Terminal Block
Earth Ground
Relay Output Rating
1A @ 24VDC
Relay Alarm Assignment
FAULT
2
*Warning signal disable for following:
The relay contact closes if Power1 and Power2 are
both failed but Power3 on.
The relay contact closes if Power3 is failed but
Power1 and Power2 are both on.
User’s Manual